Validation of Cosmed's FitMate™ in Measuring Exercise Metabolism
Authors:
- 6 March 2007
- journal article
- research article
- Published by Taylor & Francis in Research in Sports Medicine
- Vol. 15 (1) , 67-75
Abstract
The purpose of this study was to assess the validity of the FitMate metabolic system (Cosmed, Rome, Italy) in measuring oxygen consumption during graded exercise. The FitMate is a new, small (20 x 24 cm) metabolic analyzer designed for measurement of oxygen consumption during rest and exercise. Subjects included 40 healthy adults (N = 20 males, N = 20 females) ranging in age from 18 to 37 kg/m2 (mean +/- SD age, 22.5 +/- 3.6 years) and body mass index (BMI) from 18.3 to 32.5 kg/m2 (23.2 +/- 3.3 years). One-minute FitMate and Douglas bag measurements were made during steady state conditions at the end of each 3-minute stage of the Bruce treadmill graded exercise test, and subjects continued until they could not attain steady state exercise during a stage. Oxygen consumption difference scores (Douglas bag minus FitMate measurements) did not differ between males and females, so data were combined and analyzed for the entire group. During the first three stages, mean oxygen consumption did not differ significantly between the Douglas bag and FitMate systems (26.5 +/- 1.1 and 26.7 +/- 1.3 ml.kg-1.min-1, respectively, P = 0.140) with a mean absolute difference of 0.23 +/- 0.91 ml.kg-1.min-1 or 14.2 +/- 67.5 ml.min-1. In conclusion, the FitMate metabolic system accurately measures oxygen consumption during graded treadmill exercise when compared with the Douglas bag system in male and female adults.Keywords
This publication has 21 references indexed in Scilit:
- Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systemsEuropean Journal of Applied Physiology, 2006
- Validity and Stability of a Computerized Metabolic System with Mixing ChamberInternational Journal of Sports Medicine, 2004
- Validation of the portable VmaxST system for oxygen-uptake measurementGait & Posture, 2004
- Accuracy and reliability of a Cosmed K4b2 portable gas analysis systemJournal of Science and Medicine in Sport, 2004
- Validation of the MetaMax II Portable Metabolic Measurement SystemInternational Journal of Sports Medicine, 2004
- CPX/D Underestimates &OV0312;O2 in Athletes Compared with an Automated Douglas Bag SystemMedicine & Science in Sports & Exercise, 2003
- Validity and reliability of three commercially available breath-by-breath respiratory systemsEuropean Journal of Applied Physiology, 2002
- Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized systemJournal of Applied Physiology, 2001
- Validation of Aerosport KB1-C Portable Metabolic SystemInternational Journal of Sports Medicine, 1999
- Validity and Reliability of the Cosmed K2 InstrumentInternational Journal of Sports Medicine, 1993