Effect of plasma electrode position on the beam intensity of heavy ions from a RIKEN 18 GHz electron cyclotron resonance ion source
Authors:
- 1 February 2002
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 73 (2) , 598-600
Abstract
To investigate the effect of the plasma electrode position on the beam intensity, we measured the beam intensity of Ar ions, with various charge states as a function of the electrode position. In this experiment, we observed that the beam intensity of highly charged Ar ions is strongly dependent on the electrode position and that there is the suitable position to maximize the beam intensity. The optimum position varies with the charge state of ions. The beam intensity of 1.3 mA for was obtained at the optimum plasma electrode position.
Keywords
This publication has 3 references indexed in Scilit:
- Fundamental aspects of electron cyclotron resonance ion sources: From classical to large superconducting devices (invited)Review of Scientific Instruments, 2000
- Production of highly charged ions in the RIKEN 18 GHz ECR ion source using an electrode in two modesNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1999