Abstract
Novel electrochemical microsensor based on mixed iron‐ruthenium hexacyanoferrate (FeRuHCF) modified carbon fiber microelectrode (CFME) is presented for voltammetric and amperometric measurement of hydrogen peroxide at physiological pH. The FeRuHCF coating was electrochemically deposited using a one step procedure onto the substrate carbon fiber microelectrode by cycling the potential between 0.0 and +1.0 V (vs. Ag/AgCl) in a solution containing all precursor salts. The microsensor displayed good stability in neutral and alkaline media and had a nonstop working lifetime of up to 12 hours. The amperometric response time varied from 5 to 15 s depending on the hydrogen peroxide concentration level. The newly developed electrochemical microsensor exhibited a highly linear behavior in the examined concentration range from 5 to 1000 μmol L−1 (R2=0.999), an LoD (3σ) of 0.9 μmol L−1, and a favorable reproducibility with a calculated RSD of 2.9% (n= 6) for 100 μmol L−1 hydrogen peroxide, thus holding great promise for its further application in real samples and its exploitation in combination with biorecognition elements in advanced microbiosensor design.Keywords
This publication has 38 references indexed in Scilit:
- Preparation, electrochemical behavior and performance of gallium hexacyanoferrate as electrocatalyst of H2O2Electrochimica Acta, 2007
- Sol–gel derived carbon ceramic electrode for the investigation of the electrochemical behavior and electrocatalytic activity of neodymium hexacyanoferrateElectrochimica Acta, 2007
- Synthesis, characterization and performance of vanadium hexacyanoferrate as electrocatalyst of H2O2Electrochemistry Communications, 2005
- Characterization of cobalt- and copper hexacyanoferrate-modified carbon film electrodes for redox-mediated biosensorsJournal of Solid State Electrochemistry, 2005
- Clay Modified Electrodes: Present Applications and ProspectsElectroanalysis, 2003
- Electrochemical Codeposition of Platinum and Molybdenum Oxides: Formation of Composite Films with Distinct Electrocatalytic Activity for Hydrogen Peroxide DetectionElectroanalysis, 2003
- An improved Na+‐selective microelectrode for intracellular measurements in plant cellsJournal of Experimental Botany, 2001
- Analysis by X-ray photoelectron spectroscopy of ruthenium stabilised polynuclear hexacyanometallate film electrodesAnalytica Chimica Acta, 2000
- Cobalt and Copper Hexacyanoferrate Modified Carbon Fiber Microelectrode as an All-Solid Potentiometric Microsensor for HydrazineElectroanalysis, 2000
- Cathophoresis paint insulated carbon fibre ultramicro disc electrode and its application to in vivo amperometric monitoring of quantal secretion from single rat melanotrophsAnalytica Chimica Acta, 1999