Usability evaluation of an integrated electronic medication management system implemented in an oncology setting using the unified theory of acceptance and use of technology
Open Access
- 6 January 2021
- journal article
- research article
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 21 (1) , 1-11
Abstract
Background: Medication management processes in an Oncology setting are complex and difficult to examine in isolation from interrelated processes and contextual factors. This qualitative study aims to evaluate the usability of an Electronic Medication Management System (EMMS) implemented in a specialised oncology unit using the Unified Theory of Acceptance and Use of Technology (UTAUT) framework. Methods: The study was conducted in a 12-bed outpatient Oncology unit of a major teaching hospital 6 months following implementation of a commercial EMMS. In-depth semi-structured interviews were conducted with doctors, nurses and pharmacists using the system to assess usability. The UTAUT framework was used to analyse the results, which facilitated evaluation of interrelated aspects and provided a structured summary of user experience and usability factors. Results: Direct cross-comparison between user groups illustrated that doctors and pharmacists were generally satisfied with the facilitating conditions (hardware and training), but had divergent perceptions of performance (automation, standardised protocols and communication and documented) and effort (mental and temporal demand) expectancy. In counterpoint, nurses were generally satisfied across all constructs. Prior experience using an alternative EMMS influenced performance and effort expectancy and was related to early dissatisfaction with the EMMS. Furthermore, whilst not originally designed for the healthcare setting, the flexibility of the UTAUT allowed for translation to the hospital environment. Conclusion: Nurses demonstrated overall satisfaction with the EMMS, whilst doctors and pharmacists perceived usability problems, particularly related to restricted automaticity and system complexity, which hindered perceived EMMS success. The study demonstrates the feasibility and utility of the UTAUT framework to evaluate usability of an EMMS for multiple user groups in the Oncology setting.Keywords
All Related Versions
Funding Information
- Sydney Local Health District
This publication has 38 references indexed in Scilit:
- Intention to adopt clinical decision support systems in a developing country: effect of Physician’s perceived professional autonomy, involvement and belief: a cross-sectional studyBMC Medical Informatics and Decision Making, 2012
- Review of health information technology usability study methodologiesJournal of the American Medical Informatics Association, 2011
- Computerized Provider Order Entry in Pediatric Oncology: Design, Implementation, and OutcomesJournal of Oncology Practice, 2011
- Electronic Chemotherapy Order Entry: A Major Cancer Center's ImplementationJournal of Oncology Practice, 2011
- Integrated Information Systems for Electronic Chemotherapy Medication AdministrationJournal of Oncology Practice, 2011
- Does user-centred design affect the efficiency, usability and safety of CPOE order sets?Journal of the American Medical Informatics Association, 2011
- Best-of-breed versus integrated systemsAmerican Journal of Health-System Pharmacy, 2010
- Barriers to the acceptance of electronic medical records by physicians from systematic review to taxonomy and interventionsBMC Health Services Research, 2010
- Effect of computerisation on the quality and safety of chemotherapy prescriptionQuality and Safety in Health Care, 2006