Electrochemical Analysis of Chloramphenicol Using Boron-doped Diamond Electrode Applied to a Flow-Injection System
Authors:
Open Access
- 10 April 2008
- journal article
- Published by Springer Nature in Analytical Sciences
- Vol. 24 (4) , 493-498
Abstract
The electrochemical properties of chloramphenicol at a boron-doped diamond thin-film (BDD) electrode were studied using cyclic voltammetry. The highest current response of chloramphenicol was obtained with phosphate buffer, pH 6 (0.1 M) in 1% ethanol. The relationship between the concentration of chloramphenicol and the current response was linear over the range of 0.1 - 10 mM (R2 = 0.9990). The amount of chloramphenicol was analyzed by flow-injection analysis. A thin-layer flow cell equipped with a BDD electrode was used as an amperometric detector, and experiments were carried out at -0.7 V (vs. Ag/AgCl). The linear relationship between the current response and the concentration of chloramphenicol in the range of 0.1 - 50 µM (R2 = 0.9948) and the limit of detection of 0.03 µM (S/N = 3) were obtained. This method has been successfully applied to the determination of chloramphenicol in sterile eye drops and milk sample by the standard addition method. The average recoveries of chloramphenicol in eye drops were 98.0%, and the average recoveries of chloramphenicol from spiked milk were 93.9 - 103%.Keywords
This publication has 35 references indexed in Scilit:
- Determination of chloramphenicol residues in animal feeds by liquid chromatography with photo-diode array detectionAnalytica Chimica Acta, 2006
- ELISA qualitative screening of chloramphenicol in muscle, eggs, honey and milk: method validation according to the Commission Decision 2002/657/EC criteriaAnalytica Chimica Acta, 2005
- Screening, determination and confirmation of chloramphenicol in seafood, meat and honey using ELISA, HPLC–UVD, GC–ECD, GC–MS–EI–SIM and GCMS–NCI–SIM methodsAnalytica Chimica Acta, 2005
- Electrochemical oxidation of tiopronin at diamond film electrodes and its determination by amperometric flow injection analysisAnalytica Chimica Acta, 2003
- Determination of the antibiotic chloramphenicol in meat and seafood products by liquid chromatography–electrospray ionization tandem mass spectrometryJournal of Chromatography A, 2003
- Determination of chloramphenicol in animal tissues and urineAnalytica Chimica Acta, 2003
- Screening and confirmation of chloramphenicol in shrimp tissue using ELISA in combination with GC–MS2 and LC–MS2Analytica Chimica Acta, 2003
- Voltammetric determination of chloramphenicol in milk at electrochemically activated carbon fibre microelectrodesAnalytica Chimica Acta, 2002
- Determination and separation of chloramphenicol and its hydrolysate in eye-drops by capillary zone electrophoresis with amperometric detectionAnalytica Chimica Acta, 1999
- Anthraquinonedisulfonate Electrochemistry: A Comparison of Glassy Carbon, Hydrogenated Glassy Carbon, Highly Oriented Pyrolytic Graphite, and Diamond ElectrodesAnalytical Chemistry, 1998