Multireader Study on the Diagnostic Accuracy of Ultrafast Breast Magnetic Resonance Imaging for Breast Cancer Screening
- 1 October 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 53 (10) , 579-586
Abstract
Objectives: Breast cancer screening using magnetic resonance imaging (MRI) has limited accessibility due to high costs of breast MRI. Ultrafast dynamic contrast-enhanced breast MRI can be acquired within 2 minutes. We aimed to assess whether screening performance of breast radiologist using an ultrafast breast MRI-only screening protocol is as good as performance using a full multiparametric diagnostic MRI protocol (FDP). Materials and Methods: The institutional review board approved this study, and waived the need for informed consent. Between January 2012 and June 2014, 1791 consecutive breast cancer screening examinations from 954 women with a lifetime risk of more than 20% were prospectively collected. All women were scanned using a 3 T protocol interleaving ultrafast breast MRI acquisitions in a full multiparametric diagnostic MRI protocol consisting of standard dynamic contrast-enhanced sequences, diffusion-weighted imaging, and T2-weighted imaging. Subsequently, a case set was created including all biopsied screen-detected lesions in this period (31 malignant and 54 benign) and 116 randomly selected normal cases with more than 2 years of follow-up. Prior examinations were included when available. Seven dedicated breast radiologists read all 201 examinations and 153 available priors once using the FDP and once using ultrafast breast MRI only in 2 counterbalanced and crossed-over reading sessions. Results: For reading the FDP versus ultrafast breast MRI alone, sensitivity was 0.86 (95% confidence interval [CI], 0.81–0.90) versus 0.84 (95% CI, 0.78–0.88) (P = 0.50), specificity was 0.76 (95% CI, 0.74–0.79) versus 0.82 (95% CI, 0.79–0.84) (P = 0.002), positive predictive value was 0.40 (95% CI, 0.36–0.45) versus 0.45 (95% CI, 0.41–0.50) (P = 0.14), and area under the receiver operating characteristics curve was 0.89 (95% CI, 0.82–0.96) versus 0.89 (95% CI, 0.82–0.96) (P = 0.83). Ultrafast breast MRI reading was 22.8% faster than reading FDP (P < 0.001). Interreader agreement is significantly better for ultrafast breast MRI (κ = 0.730; 95% CI, 0.699–0.761) than for the FDP (κ = 0.665; 95% CI, 0.633–0.696). Conclusions: Breast MRI screening using only an ultrafast breast MRI protocol is noninferior to screening with an FDP and may result in significantly higher screening specificity and shorter reading time.Keywords
This publication has 39 references indexed in Scilit:
- Cost-Effectiveness of Screening Women With Familial Risk for Breast Cancer With Magnetic Resonance ImagingJNCI: Journal of the National Cancer Institute, 2013
- Cost-effectiveness of MRI for breast cancer screening in BRCA1/2 mutation carriersBMC Cancer, 2013
- Cost‐effectiveness of alternating magnetic resonance imaging and digital mammography screening in BRCA1 and BRCA2 gene mutation carriersCancer, 2012
- Recent Developments in the Dorfman-Berbaum-Metz Procedure for Multireader ROC Study AnalysisAcademic Radiology, 2008
- Breast MRI: guidelines from the European Society of Breast ImagingEuropean Radiology, 2008
- American Cancer Society Guidelines for Breast Screening with MRI as an Adjunct to MammographyCA: A Cancer Journal for Clinicians, 2007
- Cost-effectiveness of screening with contrast enhanced magnetic resonance imaging vs X-ray mammography of women at a high familial risk of breast cancerBritish Journal of Cancer, 2006
- Expert heads a'rollingThe Lancet, 2005
- Breast magnetic resonance image screening and ductal lavage in women at high genetic risk for breast carcinomaCancer, 2004
- Receiver Operating Characteristic Rating AnalysisInvestigative Radiology, 1992