INVESTIGATION OF PARTIAL VOLUME EFFECT IN DIFFERENT PET/CT SYSTEMS: A COMPARISON OF RESULTS USING THE MADEIRA PHANTOM AND THE NEMA NU-2 2001 PHANTOM
Authors:
- 2 March 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 169 (1-4) , 365-370
Abstract
Positron emission tomography combined with computed tomography (PET/CT) is a quantitative technique used for diagnosing various diseases and for monitoring treatment response for different types of tumours. However, the accuracy of the data is limited by the spatial resolution of the system. In addition, the so-called partial volume effect (PVE) causes a blurring of image structures, which in turn may cause an underestimation of activity of a structure with high-activity content. In this study, a new phantom, MADEIRA (Minimising Activity and Dose with Enhanced Image quality by Radiopharmaceutical Administrations) for activity quantification in PET and single photon emission computed tomography (SPECT) was used to investigate the influence on the PVE by lesion size and tumour-to-background activity concentration ratio (TBR) in four different PET/CT systems. These measurements were compared with data from measurements with the NEMA NU-2 2001 phantom. The results with the MADEIRA phantom showed that the activity concentration (AC) values were closest to the true values at low ratios of TBR (<10) and reduced to 50 % of the actual AC values at high TBR (30–35). For all scanners, recovery of true values became closer to 1 with an increasing diameter of the lesion. The MADEIRA phantom showed good agreement with the results obtained from measurements with the NEMA NU-2 2001 phantom but allows for a wider range of possibilities in measuring image quality parameters.Keywords
Funding Information
- Swedish Radiation Safety Authority (SSM)
This publication has 12 references indexed in Scilit:
- Impact of 18F-Choline PET/CT in Prostate Cancer Patients with Biochemical Recurrence: Influence of Androgen Deprivation Therapy and Correlation with PSA KineticsJournal of Nuclear Medicine, 2013
- Initial tests of a new phantom for investigation of spatial resolution, partial volume effect and detectability in nuclear medicine tomographyJournal of Physics: Conference Series, 2011
- Physical Performance of the new hybrid PET/CT Discovery-690Medical Physics, 2011
- Partial volume correction strategies for quantitative FDG PET in oncologyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- Minimising activity and dose with enhanced image quality by radiopharmaceutical administrationsRadiation Protection Dosimetry, 2010
- The Use of F-18 Choline PET in the Assessment of Bone Metastases in Prostate Cancer: Correlation with Morphological Changes on CTMolecular Imaging and Biology, 2009
- New radiopharmaceuticals for cancer diagnosis2007
- Partial-Volume Effect in PET Tumor ImagingJournal of Nuclear Medicine, 2007
- Biases affecting the measurements of tumor-to-background activity ratio in PETIEEE Transactions on Nuclear Science, 2002
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1979