Are Movement Artifacts in Magnetic Resonance Imaging a Real Problem?—A Narrative Review
Open Access
- 30 May 2017
- journal article
- review article
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 8, 232
Abstract
1. Abstract Movement artefacts compromise image quality and may interfere with interpretation, especially in MRI applications with low signal to noise ratio such as functional MR or diffusion tensor imaging, and when imaging small lesions. High image resolution has high sensitivity to motion artefacts, and often prolongs scan time that again aggravates movement artefacts. During the scan fast imaging techniques and sequences, optimal receiver coils, careful patient positioning and instruction may minimize movement artefacts. Physiological noise sources are motion from respiration, flow and pulse coupled to cardiac cycles, from the swallowing reflex and small spontaneous head movements. Par example, in resting state functional MRI spontaneous neuronal activity adds 1-2% of signal change, even under optimal conditions signal contributions from physiological noise remain a considerable fraction hereof. Movement tracking during imaging may allow for prospective correction or postprocessing steps separating signal and noise.Keywords
This publication has 62 references indexed in Scilit:
- The influence of head motion on intrinsic functional connectivity MRINeuroImage, 2012
- Physiological noise and signal-to-noise ratio in fMRI with multi-channel array coilsNeuroImage, 2011
- Navigator accuracy requirements for prospective motion correctionMagnetic Resonance in Medicine, 2009
- Sources of functional magnetic resonance imaging signal fluctuations in the human brain at rest: a 7 T studyMagnetic Resonance Imaging, 2009
- Prospective head‐movement correction for high‐resolution MRI using an in‐bore optical tracking systemMagnetic Resonance in Medicine, 2009
- Strategies for reducing respiratory motion artifacts in renal perfusion imaging with arterial spin labelingMagnetic Resonance in Medicine, 2009
- Influence of heart rate on the BOLD signal: The cardiac response functionNeuroImage, 2009
- Making the most of fMRI at 7 T by suppressing spontaneous signal fluctuationsNeuroImage, 2009
- The respiration response function: The temporal dynamics of fMRI signal fluctuations related to changes in respirationNeuroImage, 2008
- How long to scan? The relationship between fMRI temporal signal to noise ratio and necessary scan durationNeuroImage, 2007