Abstract
Compared to traditional counterparts, the dual-channel topology with two sets of batteries is inherently with stronger fault tolerance, higher reliability and modular design, which is attractive for electric vehicles (EVs). Nevertheless, it is potential that the two sets of EV batteries have different states of charge (SOCs), which leads to a unique requirement for operation mode, named unbalanced charging operation. In this article, a dual-channel electric-drive-reutilized onboard charger (EDROC) system incorporating an asymmetrical six-phase permanent magnet synchronous machine (ASPMSM) is studied. The unbalanced charging operation of this system is addressed by using the feature of multi-control degrees of freedom of the ASPMSM. At first, the decomposed currents of the ASPMSM are solved for both balanced and unbalanced charging cases, and then the trajectories of torque-production associated current components are depicted, indicating that a rotating field exists under the unbalanced charging operation. To tackle this issue, a current arranging method is proposed, with two constraints under consideration to ensure zero average torque generation and grid current balance, respectively. Following this, a controller shared for both operations is designed, where the carrier-based modulation without any zero-sequence signal injection is employed. Finally, the foresaid theoretical analyses are verified by experimental results.
Funding Information
  • National Natural Science Foundation of China (52177051)

This publication has 27 references indexed in Scilit: