Pencil Beam Scanning Bragg Peak FLASH Technique for Ultra-High Dose Rate Intensity-Modulated Proton Therapy in Early-Stage Breast Cancer Treatment
Open Access
Abstract
Bragg peak FLASH-RT can deliver highly conformal treatment and potentially offer improved normal tissue protection for radiotherapy patients. This study focused on developing ultra-high dose rate (≥40 Gy × RBE/s) intensity-modulated proton therapy (IMPT) for hypofractionated treatment of early-stage breast cancer. A novel tracking technique was developed to enable pencil beaming scanning (PBS) of single-energy protons to adapt the Bragg peak (BP) to the target distally. Standard-of-care PBS treatment plans of consecutively treated early-stage breast cancer patients using multiple energy layers were reoptimized using this technique, and dose metrics were compared between single-energy layer BP FLASH and conventional IMPT plans. FLASH dose rate coverage by volume (V40Gy/s) was also evaluated for the FLASH sparing effect. Distal tracking can precisely stop BP at the target distal edge. All plans (n = 10) achieved conformal IMPT-like dose distributions under clinical machine parameters. No statistically significant differences were observed in any dose metrics for heart, ipsilateral lung, most ipsilateral breast, and CTV metrics (p > 0.05 for all). Conventional plans yielded slightly superior target and skin dose uniformities with 4.5% and 12.9% lower dose maxes, respectively. FLASH-RT plans reached 46.7% and 61.9% average-dose rate FLASH coverage for tissues receiving more than 1 and 5 Gy plan dose total under the 250 minimum MU condition. Bragg peak FLASH-RT techniques achieved comparable plan quality to conventional IMPT while reaching adequate dose rate ratios, demonstrating the feasibility of early-stage breast cancer clinical applications.Keywords
Funding Information
- Varian Research Grant
This publication has 43 references indexed in Scilit:
- Irradiation in a flash: Unique sparing of memory in mice after whole brain irradiation with dose rates above 100 Gy/sRadiotherapy and Oncology, 2017
- Initial Report of a Prospective Dosimetric and Clinical Feasibility Trial Demonstrates the Potential of Protons to Increase the Therapeutic Ratio in Breast Cancer Compared With PhotonsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2016
- Intensity-Modulated Proton Therapy for Elective Nodal Irradiation and Involved-Field Radiation in the Definitive Treatment of Locally Advanced Non–Small-Cell Lung Cancer: A Dosimetric StudyClinical Lung Cancer, 2015
- Partial Breast Radiation Therapy With Proton Beam: 5-Year Results With Cosmetic OutcomesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2014
- Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in miceScience Translational Medicine, 2014
- Selection of patients for radiotherapy with protons aiming at reduction of side effects: The model-based approachRadiotherapy and Oncology, 2013
- Comparison of Electron and X-Ray Beams for Tumor Bed Boost Irradiation in Breast-Conserving TreatmentJournal of Breast Cancer, 2013
- Revisiting the ultra-high dose rate effect: implications for charged particle radiotherapy using protons and light ionsBritish Journal of Radiology, 2012
- Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10 801 women in 17 randomised trialsThe Lancet, 2011
- Should positive phase III clinical trial data be required before proton beam therapy is more widely adopted? NoRadiotherapy and Oncology, 2008