In Vitro Study of Flow Regulation for Pulmonary Insufficiency
Authors:
Open Access
- 22 August 2006
- journal article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 129 (2) , 284-288
Abstract
Given the tolerance of the right heart circulation to mild regurgitation and gradient, we study the potential of using motionless devices to regulate the pulmonary circulation. In addition, we document the flow performance of two mechanical valves. A motionless diode, a nozzle, a mechanical bileaflet valve, and a tilting disk valve were tested in a pulmonary mock circulatory system over the normal human range of pulmonary vascular resistance (PVR). For the mechanical valves, regurgitant fractions (RFs) and transvalvular pressure gradients were found to be weak functions of PVR. On the low end of normal PVR, the bileaflet and tilting disk valves fluttered and would not fully close. Despite this anomaly, the regurgitant fraction of either valve did not change significantly. The values for RF and transvalvular gradient measured varied from 4 to 7% and 4to7mmHg, respectively, at 5lpm for all tests. The diode valve was able to regulate flow with mild regurgitant fraction and trivial gradient but with values higher than either mechanical valve tested. Regurgitant fraction ranged from 2 to 17% in tests extending from PVR values of 1to4.5mmHg∕lpm at 5lpm and with concomitant increases in gradient up to 17mmHg. The regurgitant fraction for the nozzle increased from 2 to 23% over the range of PVR with gradients increasing to 18mmHg. The significant findings were: (1) the mechanical valves controlled regurgitation at normal physiological cardiac output and PVR even though they failed to close at some normal values of PVR and showed leaflet flutter; and (2) it may be possible to regulate the pulmonary circulation to tolerable levels using a motionless pulmonary valve device.Keywords
This publication has 18 references indexed in Scilit:
- Fluid Dynamics of Prosthetic Valves2007
- Comparative In Vitro Study of Bileaflet and Tilting Disk Valve Behavior in the Pulmonary PositionJournal of Biomechanical Engineering, 2006
- Mechanical valve thrombosis in a chronic animal model: differences between monoleaflet and bileaflet valves.2005
- Factors associated with impaired clinical status in long-term survivors of tetralogy of Fallot repair evaluated by magnetic resonance imagingJACC, 2004
- Guidelines for the Management of Patients With Valvular Heart DiseaseCirculation, 1998
- Mechanical valves in the pulmonary position: A reappraisalThe Journal of Thoracic and Cardiovascular Surgery, 1998
- Comparative study between St. Jude Madical and bioprosthetic valves in the right side of the heart.Japanese Circulation Journal, 1991
- Axial flow velocity patterns in a pulmonary artery model with varying degrees of valvular pulmonic stenosis: Pulsatile in vitro studiesJournal of Biomechanics, 1990
- Valve Replacement in Children: Guidelines for Selection of Prosthesis and Timing of Surgical InterventionThe Annals of Thoracic Surgery, 1987
- In-Vitro Pulsatile Flow Visualization Studies in a Pulmonary Artery ModelJournal of Biomechanical Engineering, 1985