Occupational hypersensitivity to metal salts, including platinum, in the secondary industry
Abstract
Background: Exposure to platinum group elements (PGEs) – platinum (Pt), palladium (Pd), rhodium (Rh) and iridium (Ir) – may cause acute toxicity or hypersensitivity with respiratory symptoms, urticaria and (less frequently) contact dermatitis. Our aim was to determine the prevalence and the clinical characteristics of hypersensitivity to platinum salts and to other elements of the platinum group.Methods: A total of 153 subjects working in a catalyst manufacturing and recycling factory were examined. The examination consisted of a work exposure and medical questionnaire, physical examination, skin prick test for PGEs and other common aeroallergens, and patch tests for PGEs. Skin prick tests and patch tests were performed with H2[PtCl6], K2[PtCl4], Na2[PtCl6], IrCl3, RhCl3, PdCl2, aqueous solutions at different concentrations.Results: Positive prick test reactions to Pt‐salts at various concentrations were found in 22 (14.4%) of 153 workers; eight had simultaneous reactions to all Pt‐salts tested; seven had positive responses to H2[PtCl6] only; four had simultaneous positive reactions to both H2[PtCl6] and K2[PtCl4]; three had positive reactions to H2[PtCl6] and Na2[PtCl6]. Three of 22 had positive reactions to H2[PtCl6] and IrCl3 solutions, two of these had positive reactions to H2[PtCl6], IrCl3 and RhCl3 solutions. Positive patch test reactions to platinum salts at day 2 were seen in two of 153 subjects.Conclusions: The results of this study demonstrate that Pt‐salts are important allergens in the catalyst industry and that the clinical manifestations involve both the respiratory system and the skin. Hexachloroplatinic acid should be considered the most important salt to use for skin prick tests.Keywords
This publication has 16 references indexed in Scilit:
- A revised nomenclature for allergy: An EAACI position statement from the EAACI nomenclature task forceAllergy, 2001
- A revised nomenclature for allergy: An EAACI position statement from the EAACI nomenclature task forceAllergy, 2001
- Evaluation of the health risk of platinum group metals emitted from automotive catalytic convertersScience of The Total Environment, 2001
- Effectiveness of a medical surveillance program for the prevention of occupational asthma caused by platinum salts: A nested case-control studyJournal of Allergy and Clinical Immunology, 2001
- Platinum in the environment: frequency of reactions to platinum‐group elements in patients with dermatitis and urticariaContact Dermatitis, 2000
- Exposure-effect relationship of platinum salt allergy in a catalyst production plant: Conclusions from a 5-year prospective cohort studyJournal of Allergy and Clinical Immunology, 2000
- Occupational asthmaAllergy, 1998
- The composition of the continental crustGeochimica et Cosmochimica Acta, 1995
- Cross‐sectional study of platinum salts sensitization among precious metals refinery workersAmerican Journal of Industrial Medicine, 1990
- Medical Surveillance of Platinum Refinery WorkersOccupational Medicine, 1980