Abstract
• VAMS was used for the quantification of four CVD therapy drugs to assess adherence. • LC-HRAM MS was used to quantify atenolol, lisinopril, simvastatin and valsartan. • VAMS showed no haematocrit effect because there is fixed volume sampling. • VAMS and DBS gave comparable drug concentrations for each individual volunteer. • The VAMS based assay has good potential for routine TDM for self-collected samples.

This publication has 22 references indexed in Scilit: