Volumetric absorptive microsampling (VAMS) coupled with high-resolution, accurate-mass (HRAM) mass spectrometry as a simplified alternative to dried blood spot (DBS) analysis for therapeutic drug monitoring of cardiovascular drugs
- 1 December 2018
- journal article
- research article
- Published by Stanford University Press in Clinical Mass Spectrometry
- Vol. 10, 1-8
Abstract
• VAMS was used for the quantification of four CVD therapy drugs to assess adherence. • LC-HRAM MS was used to quantify atenolol, lisinopril, simvastatin and valsartan. • VAMS showed no haematocrit effect because there is fixed volume sampling. • VAMS and DBS gave comparable drug concentrations for each individual volunteer. • The VAMS based assay has good potential for routine TDM for self-collected samples.Keywords
This publication has 22 references indexed in Scilit:
- Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative BioanalysisAnalytical Chemistry, 2014
- How do we better translate adherence research into improvements in patient care?International Journal of Clinical Pharmacy, 2013
- The Effect of Hematocrit on Bioanalysis of DBS: Results from The EBF DBS-Microsampling ConsortiumBioanalysis, 2013
- An LC–MS assay for the screening of cardiovascular medications in human samplesJournal of Chromatography B, 2013
- Bisoprolol, ramipril and simvastatin determination in dried blood spot samples using LC–HRMS for assessing medication adherenceJournal of Pharmaceutical and Biomedical Analysis, 2013
- Adherence to Cardiovascular Medications: Lessons Learned and Future DirectionsProgress in Cardiovascular Diseases, 2013
- Quantitative determination of atenolol in dried blood spot samples by LC–HRMS: A potential method for assessing medication adherenceJournal of Chromatography B, 2012
- Analytical methods used in conjunction with dried blood spotsAnalytical Methods, 2011
- LC–MS/MS method for the determination of several drugs used in combined cardiovascular therapy in human plasmaJournal of Chromatography B, 2010
- Dependence of ion intensity in electrospray mass spectrometry on the concentration of the analytes in the electrosprayed solutionAnalytical Chemistry, 1993