Calculating biological dose distributions in hadrontherapy using GATE: the BioDose actor
- 26 June 2026
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (15) , 155027
Abstract
Objective The BioDoseActor, a new tool implemented in the GATE Monte Carlo platform, aims to calculate the biological dose and its associated uncertainty for hadrontherapy treatment plans. This tool is designed to facilitate the validation of biophysical models and optimize clinical treatment planning by providing accurate biological dose distributions. Approach The BioDoseActor utilizes pre-calculated databases of the linear-quadratic coefficients α and β of cell survival curves, derived from biophysical models such as the modified MicroKinetic Model (mMKM) and the Nanodosimetry and Oxidative Stress (NanOx) model. These databases cover hydrogen, helium, lithium, carbon, and oxygen ions, with energy ranges from 0.1 MeV/u to 1000 MeV/u. The algorithm computes the biological dose using the linear-quadratic coefficients and their uncertainties, while optimizing Monte Carlo simulation parameters. Two step-size limitation methods in Geant4 (StepLimiter and StepFunction) were evaluated to balance accuracy and computation time in Spread Out Bragg Peak (SOBP) dose distributions for proton and carbon-ion beams. Main Results The StepFunction method proved more efficient than the StepLimiter, achieving a 30.6-fold acceleration factor for protons and a 2-fold acceleration factor for carbon ions while maintaining a maximum relative difference of 2% in SOBP. Optimal parameters for StepFunction were identified as α r = 8 .10 -5 , ρ r = 1 um for the clinical proton beam and (α r = 8.10 -4 , ρ r = 10 um) for the clinical carbon-ion beam. The calculated α and β coefficients and RBE values (1.2–1.5 for protons, 2–3 for carbon ions) aligned with literature. Application to a clinical carbon-ion treatment plan created by Raystation allowed us to validate the BioDoseActor and to demonstrate the tool’s capability to generate physical and biological dose maps and Dose Volume Histograms (DVHs). Significance The BioDoseActor enables direct comparison of biophysical models, supporting the integration of biological dose calculations into clinical practice. By optimizing simulation parameters, it reduces computation time without compromising accuracy, thus enhancing the feasibility of biological dose-based treatment planning in hadrontherapy.Keywords
Funding Information
- Federal Ministry for Women, Science and Research of the Republic of Austria
- LabEx PRIMES (ANR-11-LABX-0063)
This publication has 46 references indexed in Scilit:
- A methodology to abridge microdosimetric distributions without a significant loss of the spectral information needed for the RBE computation in carbon ion therapyJournal of Applied Clinical Medical Physics, 2023
- Comprehensive comparison of local effect model IV predictions with the particle irradiation data ensembleMedical Physics, 2021
- The TOPAS tool for particle simulation, a Monte Carlo simulation tool for physics, biology and clinical researchPhysica Medica, 2020
- Comparison of biophysical models with experimental data for three cell lines in response to irradiation with monoenergetic ionsPhysics and Imaging in Radiation Oncology, 2019
- Considerations on the miniaturization of detectors for in vivo dosimetry in radiotherapy: A Monte Carlo studyNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2017
- A Monte Carlo approach to the microdosimetric kinetic model to account for dose rate time structure effects in ion beam therapy with application in treatment planning simulationsMedical Physics, 2017
- Recent developments in Geant4Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Microdosimetry spectra and RBE of 1H, 4He, 7Li and 12C nuclei in water studied with Geant4Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2014
- A Mechanism-Based Approach to Predict the Relative Biological Effectiveness of Protons and Carbon Ions in Radiation TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Quantification of the Relative Biological Effectiveness for Ion Beam Radiotherapy: Direct Experimental Comparison of Proton and Carbon Ion Beams and a Novel Approach for Treatment PlanningInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010