Influence of Co-Cr Particles and Co-Cr Ions on the Growth of Staphylococcal Biofilms
- 1 September 2011
- journal article
- research article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 34 (9) , 759-765
Abstract
Purpose: In the last decades, hip prostheses with a metal-on-metal (MOM) bearing have been implanted by orthopedic surgeons worldwide. However, concerns are now raised towards the metal particles and degradation products released by MOM-bearings into surrounding tissue, although effects of Co-Cr wear on infection are also unknown. Therefore, we here determine the viable volumes of staphylococcal biofilms formed on polystyrene in the absence and presence of Co-Cr particles and Co-Cr ions. Methods: Three clinically derived and two commercially available staphylococcal strains were grown in the presence of 2 mg/mL Co-Cr particles or 1000/500 μg/L Co-Cr ions derived from Co-Cr salts or from particle supernatant, under static and dynamic growth conditions. A dynamic model simulates the conditions that apply for biofilm formation in the human body, as synovial fluid in mobile patients with hip prostheses is in constant motion with accompanying shear rates. Images of 24 h old biofilms were made with confocal laser scanning microscopy and analyzed with the mathematical computer program COMSTAT, yielding the biovolume of a biofilm. X-ray photoelectron spectroscopy was performed on the particles to study their elemental surface composition. Results: Most isolates showed a tendency of reduced biofilm growth in the presence of Co-Cr particles compared to growth during exposure to metal ions, but this was only significant in one strain under the dynamic growth condition (Staphylococcus aureus 7388). Characterization of the outer surface of the particles revealed a Co-Cr oxide layer enriched by Mo relative to the bulk concentration. Conclusions: MOM bearings produce metal particles which were found to possess antibacterial characteristics under dynamic growth conditions. Further research is needed towards the clinical relevance of this finding.Keywords
This publication has 30 references indexed in Scilit:
- Metal on Metal: Is It Worth the Risk?The Journal of Arthroplasty, 2010
- Instability After Total Hip ArthroplastyThe Journal of Arthroplasty, 2008
- Metal‐on‐metal bearings in total hip arthroplasties: Influence of cobalt and chromium ions on bacterial growth and biofilm formationJournal of Biomedical Materials Research Part A, 2008
- The effect of metal ions in solution on bacterial growth compared with wear particles from hip replacementsThe Journal of Bone and Joint Surgery. British volume, 2007
- Activity Level in Young Patients With Primary Total Hip ArthroplastyThe Journal of Arthroplasty, 2007
- Metal-on-Metal Total Hip ReplacementClinical Orthopaedics and Related Research, 2005
- Mid-term results of a polyethylene-free metal-on-metal articulationThe Journal of Arthroplasty, 2004
- Retrieval study of uncemented metal–metal hip prostheses revised for early looseningBiomaterials, 2003
- The wear pattern in metal‐on‐metal hip prosthesesJournal of Biomedical Materials Research, 2001
- Metal on Metal Bearings in Hip ArthroplastyClinical Orthopaedics and Related Research, 1996