Variable Loop Gain Using Excessive Regeneration Detection for a Delayed Wide-Area Control System
Authors:
- 20 June 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (6) , 6623-6632
Abstract
Excessive time delay in the implementation of a wide-area damping controller may lead to poor time-domain response or instability of an otherwise stable closed loop system. Careful monitoring of the controller output reveals the relative phase margin as it tends toward a vanishingly small value. Design and analysis of the excessive regeneration detector for system stability migration is presented. Details of degradation are followed by the description of a variable loop gain controller to ensure stability in the presence of significant delay, with nominal controller design developed using loop shaping theory. Linear and nonlinear stability of the system is assessed with the variable loop gain controller in place. Simulations of multiple disturbance environments and time delay conditions validate the developed theory using a detailed nonlinear model of the western North American power system. Finally, a GPS spoofing algorithm is employed to demonstrate the efficacy of the approach to a malicious phasor measurement unit attack.Keywords
Funding Information
- U.S. Department of Energy (DE-SC0012671)
This publication has 23 references indexed in Scilit:
- When It's Time to Upgrade: HVdc and FACTS Renovation in the Western Power SystemIEEE Power and Energy Magazine, 2016
- Adaptive Delay Compensator for the Robust Wide-Area Damping Controller DesignIEEE Transactions on Power Systems, 2016
- Design and Implementation of Delay-Dependent Wide-Area Damping Control for Stability Enhancement of Power SystemsIEEE Transactions on Smart Grid, 2016
- PDCI damping control analysis for the western North American power system2013
- Damping of inter-area oscillations using energy storage2013
- Delay-Dependent Stability Analysis of the Power System With a Wide-Area Damping Controller EmbeddedIEEE Transactions on Power Systems, 2010
- Wide-Area Measurement-Based Stabilizing Control of Power System Considering Signal Transmission DelayIEEE Transactions on Power Systems, 2004
- Stabilizing controller input delay effect on wide-area stability control2003
- Model validation for the August 10, 1996 WSCC system outageIEEE Transactions on Power Systems, 1999
- Relations Between Attenuation and Phase in Feedback Amplifier DesignBell System Technical Journal, 1940