Semi‐LASER 1H MR spectroscopy at 7 Tesla in human brain: Metabolite quantification incorporating subject‐specific macromolecule removal
Authors:
Open Access
- 31 July 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (1) , 4-12
Abstract
Purpose: To develop an in vivo 1H short‐echo‐time semi‐LASER spectroscopy protocol at 7 Tesla (T) incorporating subject‐specific macromolecule removal.Methods: T1 constants of the major metabolites were measured with little macromolecule contribution in seven healthy volunteers and used to optimize double inversion metabolite nulling. Spectra were acquired from parietal–occipital cortex of five healthy volunteers. Metabolite‐nulled macromolecule spectra were subtracted from the metabolite spectra before fitting in the time domain with prior‐knowledge templates. Absolute metabolite concentrations were determined by referencing to the water signal, following partial volume and relaxation corrections.Results: The average signal to noise ratio, N‐acetylaspartate peak height divided by the baseline noise standard deviation, was 48 ± 6. T1 constants for N‐acetylaspartate, glutamate, creatine, and choline were 1.71 ± 0.15 s, 1.68 ± 0.19 s, 1.63 ± 0.10 s, and 1.41 ± 0.09 s, respectively. The optimal double inversion times for metabolite suppression were TI1 = 2.09 s and TI2 = 0.52 s. The coefficient of variation was less than 10% for N‐acetylaspartate, creatine, choline, and myo‐inositol, and less than 20% for glutamate and glutamine.Conclusion: Short echo‐time 1H semi‐LASER spectroscopy at 7T incorporating subject‐specific macromolecule removal yielded reproducible brain metabolite concentrations ideal for applications in disease conditions where macromolecule contributions may deviate from the norm. Magn Reson Med 74:4–12, 2015.Keywords
This publication has 54 references indexed in Scilit:
- Reproducibility of brain spectroscopy at 7T using conventional localization and spectral editing techniquesJournal of Magnetic Resonance Imaging, 2013
- Localized 1H NMR spectroscopy in different regions of human brain in vivo at 7 T: T2 relaxation times and concentrations of cerebral metabolitesNMR in Biomedicine, 2011
- Applications of multi-nuclear magnetic resonance spectroscopy at 7TWorld Journal of Radiology, 2011
- In vivo 1H NMR spectroscopy of the human brain at high magnetic fields: Metabolite quantification at 4T vs. 7TMagnetic Resonance in Medicine, 2009
- Short echo time 1H‐MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulsesMagnetic Resonance in Medicine, 2007
- Linear discriminant analysis of brain tumour 1H MR spectra: a comparison of classification using whole spectra versus metabolite quantificationNMR in Biomedicine, 2007
- Automatic quantitation of localized in vivo1H spectra with LCModelNMR in Biomedicine, 2001
- Application of Multiple Inversion Recovery for Suppression of Macromolecule Resonances in Short Echo Time 1H NMR Spectroscopy of Human BrainJournal of Magnetic Resonance, 1999
- Estimation of metabolite concentrations from localized in vivo proton NMR spectraMagnetic Resonance in Medicine, 1993
- Improved quantification of in vivo1H NMR spectra by optimization of signal acquisition and processing and by incorporation of prior knowledge into the spectral fittingMagnetic Resonance in Medicine, 1990