Abstract
In the infrared thermography (IRT), computation of the temperature is very important to characterise the defect in a structure and depends upon the thermal signature of that structure. Thermal signature of some low emissive surfaces and sub-surface abnormalities is very small and often lost in the noise. Here, we report an excellent thermo-elastic behaviour of the graphene nanoplatelets (GNP) - Glass Fiber Reinforced Polymer (GFRP) composite beams. GNPs were spray-coated on the GFRP beam with different initial electrical resistances (1kΩ, 7kΩ, 21kΩ and 170 kΩ). The real-time variation in the surface temperature of GNP-GFRP beams as well as neat beam was monitored by IRT under different mechanical loading conditions. We have observed that the GNP-GFRP beam with a number density of GNPs corresponding to the 1 kΩ resistance has shown an increase in the surface temperature by 100 % in the uniaxial loading and 300 % in the stepped loading and unloading cycles, respectively. Interestingly, the GNP-GFRP beams with a number density of GNPs correspond to 21kΩ and 170kΩ have shown a decrease in the temperature as compared to a neat GFRP specimen under the similar loading conditions. These findings are important in the usage of GNPs as smart coatings for the thermal management of the composite surfaces.

This publication has 22 references indexed in Scilit: