Comparative study of inflammatory response and adhesions formation after fixation of different meshes for inguinal hernia repair in rabbits
Open Access
- 1 October 2005
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Acta Cirurgica Brasileira
- Vol. 20 (5) , 347-352
Abstract
PURPOSE: Compare, in a rabbit model, the inflammatory response and adhesions formation following surgical fixation of polypropilene and Vypro mesh in the inguinal preperitoneal space. METHODS: Fourteen male New Zealand rabbits, weighing between 2.000 to 2.500 g were used. A midline incision was made and the peritoneal cavity was exposed. The 2,0X1,0 cm polypropylene mesh was fixed in the left flank and secured to the margins with 3-0 prolene in a separate pattern. In the right flank, a 2,0X1,0 cm Vypro II mesh was sewn in the same way. After the post surgical period, the animals were again anesthetized and underwent laparoscopic approach, in order to identify and evaluate adhesions degree. Both fixed prosthesis were excised bilaterally with the abdominal wall segment, including peritoneum, aponeurosis and muscle and sent to a pathologist RESULTS: Operative time ranged from 15 to 25 minutes and no difficulties in applying the mesh were found. From the 14 polypropylene meshes fixed to the intact peritoneum, 11 had adhesions to the abdominal cavity (78,6%). Concerning Vypro mesh, 12 animals developed adhesions from the 14 with mesh fixation (85,7%). Histological examination of tissues harvested revealed fibroblasts, collagen, macrophages and lymphocytes between the threads of the mesh. CONCLUSION: Polypropylene and Vypro mesh, when implanted in the peritoneal cavity of rabbits provoke similar amount of adhesions. Vypro mesh tissues had higher fibrosis resulting in better mesh incorporation to the abdominal wall.Keywords
This publication has 10 references indexed in Scilit:
- Functional and morphologic properties of a modified mesh for inguinal hernia repairWorld Journal of Surgery, 2002
- Adhesions After Intraperitoneal Mesh Repair in Pigs: Prolene™ vs. Vypro™Journal of Laparoendoscopic & Advanced Surgical Techniques, 2002
- Evaluation of Sepramesh Biosurgical Composite in a Rabbit Hernia Repair ModelJournal of Surgical Research, 2000
- An Experimental Study of the Adhesive Potential of Different MeshesBritish Journal of Surgery, 2000
- Prevention of Adhesions to Polypropylene Mesh in a Rabbit ModelThe American Surgeon™, 1999
- Influence of polyglactin-coating on functional and morphological parameters of polypropylene-mesh modifications for abdominal wall repairBiomaterials, 1999
- The Outcomes of Nonabsorbable Mesh Placed Within the Abdominal Cavity: Literature Review and Clinical ExperienceJournal of the American College of Surgeons, 1998
- Effects of Polyglycolic Acid and Polypropylene Meshes on Postoperative Adhesion Formation in MiceWorld Journal of Surgery, 1997
- Integration of biomaterials implanted into abdominal wall: process of scar formation and macrophage responseBiomaterials, 1995
- Localized prevention of postsurgical adhesion formation and reformation with oxidized regenerated celluloseJournal of Biomedical Materials Research, 1987