CMOS micromachined cantilever-in-cantilever devices with magnetic actuation
Authors:
- W. AllegrettoWAW. Allegretto
- M. HuMHM. Hu
- A.M. RobinsonARA.M. Robinson
- 1 July 1996
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 17 (7) , 372-374
Abstract
A novel magnetically actuated cantilever microactuator which produces a large angular deflection is described. The device is a nested cantilever structure for improved sensitivity, and is fabricated entirely using a standard CMOS process. The cantilever deflects bidirectionally, and has a static deflection of more than 2.5/spl deg/. It has a response time of 25 /spl mu/s and at resonance has a deflection of more than 25/spl deg/.Keywords
This publication has 5 references indexed in Scilit:
- Thermally actuated CMOS micromirrorsSensors and Actuators A: Physical, 1995
- Silicon micromachining technology for sub-nanogram discrete mass resonant biosensorsCanadian Journal of Physics, 1992
- Micromachined thermal radiation emitter from a commercial CMOS processIEEE Electron Device Letters, 1991
- Deformable-Mirror Spatial Light Modulators1990
- Micromechanical light modulator array fabricated on siliconApplied Physics Letters, 1977