PDMS based photonic lab-on-a-chip for the selective optical detection of heavy metal ions
- 14 December 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (3) , 839-844
Abstract
The selective absorbance detection of mercury(II) (Hg2+) and lead(II) (Pb2+) ions using ferrocene-based colorimetric ligands and miniaturized multiple internal reflection (MIR) systems implemented in a low-cost photonic lab on a chip (PhLoC) is reported. The detection principle is based on the formation of selective stable complexes between the heavy metal ion and the corresponding ligand. This interaction modulates the ligand spectrum by giving rise to new absorbance bands or wavelength shifting of the existing ones. A comparative study for the detection of Hg2+ was carried out with two MIR-based PhLoC systems showing optical path lengths (OPLs) of 0.64 cm and 1.42 cm as well as a standard cuvette (1.00 cm OPL). Acetonitrile solutions containing the corresponding ligand and increasing concentrations of the heavy metal ion were pumped inside the systems and the absorbance in the visible region of the spectra was recorded. The optical behaviour of all the tested systems followed the expected Beer–Lambert law. Thus, the best results were achieved with the one with the longest OPL, which showed a linear behaviour in a concentration range of 1 μM–90 μM Hg2+, a sensitivity of 5.6 × 10−3 A.U. μM−1 and a LOD of 2.59 μM (0.49 ppm), this being 1.7 times lower than that recorded with a standard cuvette, and using a sample/reagent volume around 190 times smaller. This microsystem was also applied for the detection of Pb2+ and a linear behaviour in a concentration range of 3–100 μM was obtained, and a sensitivity of 9.59 × 10−4 A.U. μM−1 and a LOD of 4.19 μM (0.868 ppm) were achieved. Such a simple analytical tool could be implemented in portable instruments for automatic in-field measurements and, considering the minute sample and reagent volume required, would enable the deployment of high throughput environmental analysis of these pollutants and other related hazardous species.Keywords
This publication has 36 references indexed in Scilit:
- Single-labeled hairpin probe for highly specific and sensitive detection of lead(II) based on the fluorescence quenching of deoxyguanosine and G-quartetBiosensors and Bioelectronics, 2013
- A polymer lab chip sensor with microfabricated planar silver electrode for continuous and on-site heavy metal measurementSensors and Actuators B: Chemical, 2011
- Photonic crystal hydrogel material for the sensing of toxic mercury ions (Hg2+) in waterSoft Matter, 2011
- Development and Applications of Fluorogenic Probes for Mercury(II) Based on Vinyl Ether OxymercurationJournal of the American Chemical Society, 2011
- Label-free DNAzyme-based fluorescing molecular switch for sensitive and selective detection of lead ionsChemical Communications, 2011
- A label-free colorimetric detection of lead ions by controlling the ligand shells of gold nanoparticlesTalanta, 2010
- Electrochemical Microsensors for the Detection of Cadmium(II) and Lead(II) Ions in PlantsSensors, 2010
- Towards an Efficient Microsystem for the Real‐Time Detection and Quantification of Mercury in Water Based on a Specifically Designed Fluorogenic Binary Task‐Specific Ionic LiquidAngewandte Chemie International Edition, 2009
- Investigation into mercury bound to biothiols: structural identification using ESI–ion-trap MS and introduction of a method for their HPLC separation with simultaneous detection by ICP-MS and ESI-MSAnalytical and Bioanalytical Chemistry, 2008
- On-chip generated mercury microelectrode for heavy metal ion detectionLab on a Chip, 2004