Maximal Electrogram Attenuation Recorded from Mini Electrodes Embedded on 4.5‐mm Irrigated and 8‐mm Nonirrigated Catheters Signifies Lesion Maturation
Authors:
- 2 December 2014
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 26 (2) , 192-202
Abstract
The electrograms (EGMs) recorded from mini electrodes (ME) placed on the tip of the ablation electrode allow more precise EGM monitoring during lesion formation. Our objective was to define the lesion boundaries and extracardiac injuries resulting from 60-second RF application versus RF application time titrated to maximal attenuation of the ME EGM in the atria and ventricles using 4.5-mm irrigated and 8-mm catheters. RF lesions were placed in both atria and ventricles in 13 (30-35 kg) canines; 6 (4.5-mm OI) and 7 (8 mm). The RF application time was fixed at 60 seconds or terminated at maximal ME EGM amplitude attenuation. Pre/postablation pacing thresholds, EGM amplitudes, and lesion dimensions were not significantly different between maximal EGM attenuation and 60-second RF application using either catheter. Atrial lesion transmurality was also similar for both catheters and groups 91.2% (4.5 mm) and 96% (8 mm) when the RF was titrated to the maximal EGM attenuation and 94.2% (4.5 mm) and 95% (8 mm) with 60-second RF. The 60-second RF ablation, however, presented with significant extracardiac injuries to the lungs and esophagus, along with char formation. Deep ventricular lesions were noted with maximal EGM attenuation that were not different from the 60-second RF ablation. Titration of the RF application time to the maximal EGM attenuation based on the ME recordings represents atrial lesion maturation and deep ventricular lesions. Prolonging the RF application results in greater extracardiac injury and char formation without increasing lesion size.Keywords
Funding Information
- Boston Scientific Corporation (BSC), Natick, MA, USA
This publication has 15 references indexed in Scilit:
- Reproducibility of left atrial ablation with high-intensity focused ultrasound energy in a calf modelThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Esophageal Injury and Temperature Monitoring During Atrial Fibrillation AblationCirculation: Arrhythmia and Electrophysiology, 2008
- Analysis of Catheter-Tip (8-mm) and Actual Tissue Temperatures Achieved During Radiofrequency Ablation at the Orifice of the Pulmonary VeinCirculation, 2004
- Left Atrial–Esophageal Fistula Following Radiofrequency Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2004
- Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial FibrillationCirculation, 2004
- Identification of Transmural Necrosis Along a Linear Catheter Ablation Lesion During Atrial Fibrillation and Sinus RhythmJournal of Interventional Cardiac Electrophysiology, 2003
- Lesion Dimensions During Temperature-Controlled Radiofrequency Catheter Ablation of Left Ventricular Porcine MyocardiumCirculation, 1999
- Comparison of In Vivo Tissue Temperature Profile and Lesion Geometry for Radiofrequency Ablation With a Saline-Irrigated Electrode Versus Temperature Control in a Canine Thigh Muscle PreparationCirculation, 1995
- Physics and engineering of transcatheter cardiac tissue ablationJACC, 1993
- Left Ventricular Wall Thickness Determined by Ultrasound in 100 Subjects without Heart DiseaseChest, 1971