A Comparison of 226- and 1000-Hz Probe Tone Tympanometry With Myringotomy Findings in Infants
- 2 December 2024
- journal article
- research article
- Published by American Speech Language Hearing Association in American Journal of Audiology
- Vol. 33 (4) , 1246-1256
Abstract
Purpose: This study aimed to verify the diagnostic value of tympanometry with 226- and 1000-Hz probe tones in infants by comparing tympanometry results with the gold standard of the middle ear state assessed by myringotomy. Furthermore, clinically useful predictors for false peaked tympanograms despite the presence of middle ear fluid should be identified. Method: Pre-operative 226- and 1000-Hz tympanograms were retrospectively compared with intraoperative findings of the tympanic cavity after myringotomy in 111 infants (217 ears) aged ≤ 12 months. In addition to the shape of tympanograms, demographic and clinical characteristics, the results of other audiometric measurements, and the viscosity of middle ear fluid, if present, were evaluated in several subgroups. Results: The sensitivity and specificity of 1000-Hz tympanometry for middle ear effusion (MEE) detection were 97%–98% and 71%–84%, respectively, whereas standard tympanometry with a 226-Hz probe tone achieved a poor sensitivity of 43%–61% and a specificity of 81%–97%. Younger age, low viscosity of the middle ear fluid, and female sex were associated with an increased risk of false peaked 226-Hz tympanograms despite MEE. Furthermore, larger equivalent outer ear canal volumes were linked to false peaked 226-Hz tympanograms. Conclusions: The comparison of myringotomy findings and 226- and 1000-Hz tympanometry confirms the superiority of high-frequency tympanometry in infants younger than 12 months. Although this study identified some vague predictors of potentially false peaked 226-Hz tympanograms, the assessment of the middle ear state by 226-Hz tympanometry remains unreliable in young infants.Keywords
This publication has 34 references indexed in Scilit:
- Neonatal hearing screening - does failure in TEOAE screening matter when the AABR test is passed?European Archives of Oto-Rhino-Laryngology, 2023
- Middle ear effusion and newborn hearing screeningEuropean Archives of Oto-Rhino-Laryngology, 2022
- Newborn hearing screening: Prevalence and medical and paramedical treatment of bilateral hearing loss in a neonatal series in the Île-de-France region of FranceEuropean Annals of Otorhinolaryngology, Head and Neck Diseases, 2016
- Developmental outcomes of early-identified children who are hard of hearing at 12 to 18months of ageEarly Human Development, 2015
- A comparison of tympanometry with 226 Hz and 1000 Hz probe tones in children with Down syndromeInternational Journal of Pediatric Otorhinolaryngology, 2011
- Impedance audiometry in infants with a cleft palate: The standard 226-Hz probe tone has no predictive value for the middle ear conditionInternational Journal of Pediatric Otorhinolaryngology, 2010
- Tympanometry in infants with middle ear effusion having been identified using spiral computerized tomographyAmerican Journal of Otolaryngology, 2010
- Failed newborn hearing screens as presentation for otitis media with effusion in the newborn populationInternational Journal of Pediatric Otorhinolaryngology, 2005
- Mechanisms of hearing loss resulting from middle-ear fluidHearing Research, 2004
- Clinical Experience With Impedance AudiometryJAMA Otolaryngology–Head & Neck Surgery, 1970