Effect of agitation in the hydrogenation of castor oil
- 1 August 1997
- journal article
- Published by Wiley in Journal of the American Oil Chemists' Society
- Vol. 74 (8) , 957-962
Abstract
Castor oil was hydrogenated to evaluate the effect of agitation during hydrogenation. The turbine and propeller impellers were evaluated during hydrogenation of castor oil at various temperatures, pressures, and catalyst concentrations. The effect of impeller position in the agitator at definite oil depth was also evaluated. Hydrogenation of castor oil at 130°C, 2.0 kg/cm2 hydrogen gas pressure with 0.5% Ni catalyst for 6 h while using two turbine impellers fitted in an agitator, one close to the reactor bottom and another at a height just below the top oil layer, revolving at 350 rpm, resulted in a product of a iodine value of 4.1, hydroxyl value of 156.4, and slip point of 84°C.Keywords
This publication has 6 references indexed in Scilit:
- Kinetics of hydrogenation of rapeseed oil: I. Influence of transport steps in kinetic studyJournal of the American Oil Chemists' Society, 1975
- Mixing effects in dead end hydrogenation of oils: Sulfite oxidation modelJournal of the American Oil Chemists' Society, 1971
- The occurrence of minimum stirring rates in gas—liquid reactorsChemical Engineering Science, 1968
- Mixing effects in dead‐end hydrogenationJournal of the American Oil Chemists' Society, 1967
- The residence time distribution of the gas in an agitated gas-liquid contactorChemical Engineering Science, 1963
- Effect of agitation on selectivity in the hydrogenation of soybean oilJournal of the American Oil Chemists' Society, 1954