Paramedic Student Clinical Performance During High-Fidelity Simulation After a Physically Demanding Occupational Task
Authors:
- Alex (Sandy) BSc MacQuarrieAMAlex (Sandy) BSc MacQuarrie
- Jayden R. Bed (Pe)(Hons) HunterJHJayden R. Bed (Pe)(Hons) Hunter
- Samantha Bsc SheridanSSSamantha Bsc Sheridan
- Amanda Bsc HlushakAHAmanda Bsc Hlushak
- Clare BSc(Hons) SuttonCSClare BSc(Hons) Sutton
- James Bsc (Hons) WickhamJWJames Bsc (Hons) Wickham
- 3 November 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare
- Vol. 17 (4) , 234-241
Abstract
Introduction: Paramedic duties include assessing, treating, and maneuvering patients in physically challenging environments. Whether clinical skills and patient care are affected by these occupational demands is unknown. High-fidelity simulation affords the opportunity to study this in a controlled setting. Methods: Using a randomized crossover design, 11 regional paramedicine students and graduates (mean ± SD age = 23 ± 2 years) completed two, 20-minute high-fidelity simulations that included cardiopulmonary resuscitation (CPR) immediately after either an acute bout of occupational physical activity (OPA) or a rest period (REST). Heart rate, respiratory rate, and mean arterial pressure were measured throughout. Clinical performance was scored using the Global Rating Score and a patient care record. Measures of CPR efficacy were recorded in the manikin. Results: There were no significant differences in Global Rating Score (P = 0.07, ES = 0.03) or CPR efficacy between conditions. Patient care record accuracy was higher after the OPA versus REST simulations (mean ± SD = 61.8 ± 12.6% vs. 55.5 ± 12.0%, P = 0.03, ES = 0.5). Mean heart rate was higher during OPA simulations versus REST simulations (121 ± 14 vs. 84 ± 9 beats per minute, P < 0.01, ES = 3.1), as was mean respiratory rate (19 ± 3 vs. 16 ± 3 breaths per minute, P < 0.01, ES = 1.0). Mean arterial pressure was higher for OPA versus REST at simulation start (105 ± 11.3 vs. 95.8 ± 11.8 mm Hg, P = 0.01, Effect Size = 0.8), although not different after simulation. Conclusions: Paramedicine students including recent graduates performed as well, or better, in a simulated clinical scenario immediately after occupation-specific acute physical exertion compared with a REST, despite higher physiological exertion. Whether this is the case for more experienced but potentially less physically fit paramedics in the workforce warrants investigation.Keywords
This publication has 20 references indexed in Scilit:
- Validation of the iHealth BP7 wrist blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010Blood Pressure Monitoring, 2014
- Simulation-based Assessment of Paramedics and Performance in Real Clinical ContextsPrehospital Emergency Care, 2013
- Physical and psychosocial work environment factors and their association with health outcomes in Danish ambulance personnel – a cross-sectional studyBMC Public Health, 2012
- Independent Effects of Sleep Duration and Body Mass Index on the Risk of a Work-Related Injury: Evidence From the US National Health Interview Survey (2004–2010)Chronobiology International, 2012
- Fatigue risk management: Organizational factors at the regulatory and industry/company levelAccident Analysis & Prevention, 2011
- Sleep Quality and Fatigue Among Prehospital ProvidersPrehospital Emergency Care, 2010
- Paramedic clinical decision making during high acuity emergency calls: design and methodology of a Delphi studyBMC Emergency Medicine, 2009
- The physiological effect on rescuers of doing 2min of uninterrupted chest compressionsResuscitation, 2007
- Obesity and Workers' CompensationArchives of internal medicine (1960), 2007
- Paramedic Performance in Calculating Drug Dosages Following Stressful Scenarios in a Human Patient SimulatorPrehospital Emergency Care, 2005