Myocardium tracking via matching distributions
- 28 October 2008
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 4 (1) , 37-44
Abstract
The goal of this study is to investigate automatic myocardium tracking in cardiac Magnetic Resonance (MR) sequences using global distribution matching via level-set curve evolution. Rather than relying on the pixelwise information as in existing approaches, distribution matching compares intensity distributions, and consequently, is well-suited to the myocardium tracking problem. Starting from a manual segmentation of the first frame, two curves are evolved in order to recover the endocardium (inner myocardium boundary) and the epicardium (outer myocardium boundary) in all the frames. For each curve, the evolution equation is sought following the maximization of a functional containing two terms: (1) a distribution matching term measuring the similarity between the non-parametric intensity distributions sampled from inside and outside the curve to the model distributions of the corresponding regions estimated from the previous frame; (2) a gradient term for smoothing the curve and biasing it toward high gradient of intensity. The Bhattacharyya coefficient is used as a similarity measure between distributions. The functional maximization is obtained by the Euler–Lagrange ascent equation of curve evolution, and efficiently implemented via level-set. The performance of the proposed distribution matching was quantitatively evaluated by comparisons with independent manual segmentations approved by an experienced cardiologist. The method was applied to ten 2D mid-cavity MR sequences corresponding to ten different subjects. Although neither shape prior knowledge nor curve coupling were used, quantitative evaluation demonstrated that the results were consistent with manual segmentations. The proposed method compares well with existing methods. The algorithm also yields a satisfying reproducibility. Distribution matching leads to a myocardium tracking which is more flexible and applicable than existing methods because the algorithm uses only the current data, i.e., does not require a training, and consequently, the solution is not bounded to some shape/intensity prior information learned from of a finite training set.Keywords
This publication has 25 references indexed in Scilit:
- Efficient and generalizable statistical models of shape and appearance for analysis of cardiac MRIMedical Image Analysis, 2008
- Automatic Segmentation of the Left Ventricle in Cardiac MR and CT ImagesInternational Journal of Computer Vision, 2006
- Left-ventricle myocardium segmentation using a coupled level-set with a priori knowledgeComputerized Medical Imaging and Graphics, 2006
- Unsupervised motion-compensation of multi-slice cardiac perfusion MRIMedical Image Analysis, 2005
- A level set approach for shape-driven segmentation and tracking of the left ventricleIEEE Transactions on Medical Imaging, 2003
- Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the HeartCirculation, 2002
- Active appearance modelsIEEE Transactions on Pattern Analysis and Machine Intelligence, 2001
- Multistage hybrid active appearance model matching: segmentation of left and right ventricles in cardiac MR imagesIEEE Transactions on Medical Imaging, 2001
- Active contours without edgesIEEE Transactions on Image Processing, 2001
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986