Simulator Wear of Some Commercially Available Metal-on-Metal Hip Implants
Authors:
- 1 January 1998
- book chapter
- Published by ASTM International
- p. 92-110
Abstract
Simulator wear tests were conducted for 1.5 million cycles on second generation metal-on-metal hip implants fabricated from cobalt-based alloy (ASTM F 1537-94) to compare their performance with each other and with both custom-made implants and retrieval studies published in the literature. In addition, factors controlling wear were explored. Six commercially available implants were tested (2 low carbon and 4 high carbon) for 1.5 million cycles in a MATCO™ hip simulator following previously established protocols. Volumetric wear was in the same range for all of the implants tested and much less than would be expected in comparable tests with conventional polyethylene cups. The wear of the commercial implants used in the present study was very similar to custom-made hip implants of similar diameter, clearance and surface roughness. Three of the high carbon implants of the present study had somewhat lower wear than expected when their surface roughness was taken into account but, in general, clearance, roughness and lambda (a ratio of lubricant film thickness to combined surface roughness) were factors controlling wear. The simulator wear of the present study showed some agreement with the in vivo wear estimated in retrieval studies in the literature.Keywords
This publication has 11 references indexed in Scilit:
- Kinematics of the MATCO™ hip simulator and issues related to wear testing of metal-metal implantsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1997
- Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacementsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1997
- Engineering Issues and Wear Performance of Metal on Metal Hip ImplantsClinical Orthopaedics and Related Research, 1996
- Metal-On-Metal Articulation for Artificial Hip Joints: Laboratory Study and Clinical ResultsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996
- In Vivo Wear of 3 Types of Metal on Metal Hip Prostheses During 2 Decades of UseClinical Orthopaedics and Related Research, 1996
- Cobalt Chromium Molybdenum Metal Combination for Modular Hip ProsthesesClinical Orthopaedics and Related Research, 1996
- Comparison of Alloys and Designs in a Hip Simulator Study of Metal on Metal ImplantsClinical Orthopaedics and Related Research, 1996
- Metal on Metal Total Hip Replacement Workshop Consensus DocumentClinical Orthopaedics and Related Research, 1996
- Untersuchung des tribologischen Verhaltens von Metall/Metall-Kombinationen für künstliche Hüftgelenke - Investigation of the Tribological Behaviour of Metal-on-Metal Combinations for Artificial Hip JointsBiomedical Engineering / Biomedizinische Technik, 1990
- The VNR Concise Encyclopedia of Mathematics1977