Validity of V̇O2max estimates from the forerunner 245 smartwatch in highly vs. moderately trained endurance athletes

Authors:

Abstract
Purpose: Assessing the validity of maximum oxygen uptake (V̇O₂ max ) estimates provided by a commercially available smartwatch (Garmin Forerunner 245, Garmin Ltd., Olathe, USA) compared to laboratory-based respiratory gas analysis in moderately-to-highly trained athletes. Methods: Thirty-five endurance athletes (Tier 2–3 athletes, 24 males, 11 females; age: 25.1 ± 3.5 years; V̇O₂ max : 60.1 ± 8.2 ml·min⁻ 1 ·kg⁻ 1 ) completed a treadmill ramp test with respiratory gas analysis to determine criterion V̇O₂ max . Additionally, each athlete performed two submaximal 15-min outdoor runs at > 70% of maximum heart rate, during which the smartwatch estimated V̇O₂ max . Athletes were stratified into moderately trained (V̇O₂ max ≤ 59.8 ml·min⁻ 1 ·kg⁻ 1 ) and highly trained (V̇O₂ max > 59.8 ml·min⁻ 1 ·kg⁻ 1 ) subgroups. Results: Across all athletes, the smartwatch underestimated V̇O₂ max [mean differences: − 4.73 ml·min⁻ 1 ·kg⁻ 1 (run 1), -4.05 ml·min⁻ 1 ·kg⁻ 1 (run 2)]. Intraclass correlation coefficients (ICC) indicated moderate agreement between smartwatch and laboratory values (run 1: ICC = 0.71 [95% CI: 0.03–0.90]; run 2: ICC = 0.75 [95% CI: 0.17–0.91]), with mean absolute percentage errors (MAPE) of 7.9% and 7.2%. Subgroup analyses revealed better accuracy of smartwatch estimated V̇O₂ max in moderately trained group (MAPE: 4.1–2.8%; ICC: 0.63–0.66 [95% CI: 0.09–0.87]), whereas in highly trained athletes, the smartwatch underestimated V̇O₂ max by 6.3 ml·min⁻ 1 ·kg⁻ 1 (MAPE: 10.4–9.4%; ICC: 0.34–0.41 [95% CI: − 0.11–0.75]). Conclusion: Smartwatch-derived V̇O₂ max estimates are valid in moderately trained athletes but less valid in highly trained individuals. While smartwatches are useful for general monitoring, caution is warranted in their interpretation, particularly in highly trained individuals. Laboratory-based gas analysis remains the preferred method when precision is required.
Funding Information
  • Julius-Maximilians-Universität Würzburg

This publication has 36 references indexed in Scilit: