Sirolimus-Eluting Stents Suppress Neointimal Formation Irrespective of Metallic Allergy
Open Access
- 1 January 2008
- journal article
- clinical trial
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 72 (6) , 893-896
Abstract
Background Metallic allergy is associated with restenosis following bare metal stent implantation, but the impact of metallic allergy on the outcome after implantation of drug-eluting stents (DES) has not been investigated. Methods and Results The present study group consisted of 88 consecutive patients (109 lesions) who underwent percutaneous coronary intervention with sirolimus-eluting stents (SES). Follow-up angiography was obtained at 8 months in all patients. At that time, the patients underwent epicutaneous patch tests for nickel, chromate, molybdenum, manganese, and titanium, which were evaluated after 48 h of contact. The patch test was positive in 14 patients (16%) (5 for manganese, 3 for nickel, 1 for chromate, 1 for Nickel and manganese, and 4 for manganese and chromate). The binary restenosis rate in the patients with a positive patch test was similar to those with negative patch test (6.3% vs 6.5%, p=0.98). Serial quantitative coronary angiography analyses identified no significant differences in late lumen loss of in-stent segments between patients with positive patch test and those with negative patch test (0.19±0.49 mm vs 0.12±0.48 mm, p=0.55). Conclusion SES prevent restenosis irrespective of metallic allergy. The classic relationship between metallic allergy and in-stent restenosis, seen with bare metal stents, does not appear to arise with DES, possibly because of the immunosuppressive effect of sirolimus. (Circ J 2008; 72: 893 - 896)Keywords
This publication has 18 references indexed in Scilit:
- Pathology of Drug-Eluting Stents in HumansJACC, 2006
- Hypersensitivity Cases Associated With Drug-Eluting Coronary StentsJACC, 2006
- Evaluation of Four-Year Coronary Artery Response After Sirolimus-Eluting Stent Implantation Using Serial Quantitative Intravascular Ultrasound and Computer-Assisted Grayscale Value Analysis for Plaque Composition in Event-Free PatientsJACC, 2005
- The impact of metallic allergy on stent implantationInternational Journal of Cardiology, 2005
- Immunosuppressive Drugs for Kidney TransplantationNew England Journal of Medicine, 2004
- Clinical, Angiographic, and Procedural Predictors of Angiographic Restenosis After Sirolimus-Eluting Stent Implantation in Complex PatientsCirculation, 2004
- Localized Hypersensitivity and Late Coronary Thrombosis Secondary to a Sirolimus-Eluting StentCirculation, 2004
- Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary ArteryNew England Journal of Medicine, 2003
- Characteristics of Metals Used in ImplantsJournal of Endourology, 1997
- Nickel release from metals, and a case of allergic contact dermatitis from stainless steelContact Dermatitis, 1994