Dark Flow Artifacts with Steady-State Free Precession Cine MR Technique: Causes and Implications for Cardiac MR Imaging
Authors:
- Wei LiWLWei Li
- Pippa StoreyPSPippa Storey
- Qun ChenQCQun Chen
- Belinda S. Y. LiBLBelinda S. Y. Li
- Pottumarthi V. PrasadPPPottumarthi V. Prasad
- Robert R. EdelmanRERobert R. Edelman
- 1 February 2004
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 230 (2) , 569-575
Abstract
Steady-state free precession cine images from cardiac magnetic resonance imaging studies of 24 patients were reviewed retrospectively to identify dark flow artifacts. The cause and features of the artifacts were studied in flow phantom experiments. Dark flow artifacts were recognized in eight of the 24 cases and were characterized by low or inhomogeneous signal intensity in blood pools with little change in adjacent tissues. The artifacts could be mimicked in flow phantom experiments by deliberately deshimming the gradients and appeared periodically during imaging with off-centered frequencies. These artifacts appeared to be caused by spins moving within an inhomogeneous magnetic field. Supplemental material: radiology.rsnajnls.org/cgi/content/full/2302021257/DC1 © RSNA, 2004Keywords
This publication has 8 references indexed in Scilit:
- Fully Refocused Gradient Recalled Echo (FRGRE): Factors Affecting Flow and Motion Sensitivity in Cardiac MRIJournal of Cardiovascular Magnetic Resonance, 2002
- MR Imaging of the Heart with Cine True Fast Imaging with Steady-State Precession: Influence of Spatial and Temporal Resolutions on Left Ventricular Functional ParametersRadiology, 2002
- Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricleJournal of Magnetic Resonance Imaging, 2001
- Functional cardiac MR imaging with steady‐state free precession (SSFP) significantly improves endocardial border delineation without contrast agentsJournal of Magnetic Resonance Imaging, 2001
- Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State PrecessionRadiology, 2001
- MR Evaluation of Ventricular Function: True Fast Imaging with Steady-State Precession versus Fast Low-Angle Shot Cine MR Imaging: Feasibility StudyRadiology, 2001
- Simultaneous calculation of flow and diffusion sensitivity in steady‐state free precession imagingMagnetic Resonance in Medicine, 1995
- Steady-state free precession imaging in the presence of motion: application for improved visualization of the cerebrospinal fluid.Radiology, 1990