Interatrial shunt closure devices in patients with nickel allergy
- 19 May 2009
- journal article
- valvular and-structural-heart-diseases
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 74 (4) , 647-651
Abstract
We assessed outcomes in nickel allergic patients treated with percutaneous interatrial shunt device closure with the Helex device. Nickel toxicity has been well described in patients undergoing interatrial shunt closure with the Amplatzer device, which has a nitinol design. There have been no reports using Helex in nickel allergic patients. Ninety‐five consecutive patients underwent percutaneous interatrial shunt closure at a single US center by one operator. In those with possible nickel allergy, patch testing with the North American Contact Dermatitis Group standard series and a metal series was performed. The mean age was 48 ± 16 years (range 18‐81), 48% were male, 21 (22%) had atrial septal defect, and 74 (78%) had patent foramen ovale. Six patients had a positive skin test to nickel and underwent successful closure with Helex. Of the remaining 89 patients, 88 were closed with Amplatzer and one with Helex. All procedures were successful with no deaths, myocardial infarctions, strokes, or systemic emboli at six‐month followup. None of the Helex patients developed an allergic reaction, significant chest pain, or arrhythmia. Of those without pre‐procedural known nickel allergy, 12% had palpitations, 5% had atrial fibrillation, and 13% had chest pain. When compared with a published report that 89% of nickel‐allergic patients developing an allergic reaction to the Amplatzer or Premere device, Helex appeared far safer in nickel allergic patients (P < 0.001). In patients with nickel allergy, percutaneous interatrial shunt device closure with Helex device is safe, and is not associated with allergy to nickel.Keywords
This publication has 15 references indexed in Scilit:
- Unusual Presentation of Nickel Allergy Requiring Explantation of an Amplatzer Atrial Septal Occluder DeviceClinical Cardiology, 2009
- Nickel Allergy in Interatrial Shunt Device-based Closure PatientsCongenital Heart Disease, 2007
- Adverse Events Associated With Nickel Allergy in Patients Undergoing Percutaneous Atrial Septal Defect or Patent Foramen Ovale ClosureJACC, 2006
- Nickel release, a possible indicator for the duration of antiplatelet treatment, from a nickel cardiac device in vivo: a study in patients with atrial septal defects implanted with an Amplatzer occlInt. Journal of Clinical Pharmacology and Therapeutics, 2006
- Pericarditis associated with nickel hypersensitivity to the Amplatzer occluder device: A case reportCatheterization and Cardiovascular Interventions, 2005
- Nickel release after implantation of the Amplatzer occluderAmerican Heart Journal, 2003
- Systemic allergic reaction to the percutaneous patent foramen ovale occluderThe Journal of Thoracic and Cardiovascular Surgery, 2003
- Treatment of Complex Arteriosclerotic Lesions with Nitinol Stents in the Superficial Femoral and Popliteal Arteries: A Midterm Follow-upRadiology, 2002
- Dissolution of nickel and tissue response observed by X-ray scanning analytical microscopyBiomaterials, 1999
- Electrochemical and surface characterization of a nickel–titanium alloyBiomaterials, 1998