Modeling and Analysis of the W7-X High Heat-Flux Divertor Scraper Element
- 21 February 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 42 (3) , 545-551
Abstract
The Wendelstein 7-X stellarator experiment is scheduled for the completion of device commissioning and the start of first plasma in 2015. At the completion of the first two operational phases, the inertially cooled test divertor unit will be replaced with an actively cooled high heat-flux divertor, which will enable the device to increase its pulse length to steady-state plasma performance. Plasma simulations show that the evolution of bootstrap current in certain plasma scenarios produce excessive heat fluxes on the edge of the divertor targets. It is proposed to place an additional scraper element in the 10 divertor locations to intercept some of the plasma flux and reduce the heat load on these divertor edge elements. Each scraper element may experience a 500-kW steady-state power load, with localized heat fluxes as high as 20 MW/m2. Computational analysis has been performed to examine the thermal integrity of the scraper element. The peak temperature in the carbon-carbon fiber composite, the total pressure drop in the cooling water, and the increase in water temperature must all be examined to stay within specific design limits. Computational fluid dynamics modeling is performed to examine the flow paths through the multiple monoblock fingers as well as the thermal transfer through the monoblock swirl tube channels.Keywords
This publication has 10 references indexed in Scilit:
- Design and Analysis of Divertor Scraper Elements for the W7-X StellaratorIEEE Transactions on Plasma Science, 2014
- Results and consequences of high heat flux testing as quality assessment of the Wendelstein 7-X divertorFusion Engineering and Design, 2013
- Design and analysis of the W7-X divertor scraper elementFusion Engineering and Design, 2013
- Wendelstein 7-X high heat flux components2013
- Heat transfer enhancement in a tube with twisted tape inserts placed separately from the tube wallExperimental Thermal and Fluid Science, 2012
- Assessment of CFC grades under thermal fatigue for the ITER inner vertical targetPhysica Scripta, 2011
- Design analysis and manufacturing of the cooling lines of the in vessel components of WENDELSTEIN 7-XFusion Engineering and Design, 2011
- ITER Relevant High Heat Flux Testing on Plasma Facing SurfacesMATERIALS TRANSACTIONS, 2005
- ITER divertor, design issues and research and developmentFusion Engineering and Design, 1999
- Heat Transfer and Pressure Drop Correlations for Twisted-Tape Inserts in Isothermal Tubes: Part II—Transition and Turbulent FlowsJournal of Heat Transfer, 1993