Background To evaluate the effect of the Valsalva maneuver (VM) on short-term variations of intraocular pressure (IOP) and ocular pulse amplitude (OPA) values in healthy, young, male subjects. Methods IOP and OPA values were measured before and during VM by Pascal dynamic contour tonometer (DCT) in 55 eyes of 55 healthy male volunteers aged 20 through 27 years. Results Mean IOP before VM was 17.2 ± 2.9 mmHg and during the VM was 19.8 ± 4 mmHg. The increase in mean IOP during the VM was found to be statistically significant (p = 0.001). The IOP increased in 46 (83.6%) of 55 eyes. However, in nine eyes (16.4%), IOP decreased during the VM. Mean OPA value before VM was 3.6 ± 1.4 mmHg and during the VM was 3.6 ± 1.3 mmHg. The change in mean OPA value was found to be statistically insignificant (p = 0.9). Conclusions The IOP significantly increases during VM, whereas OPA remains stable. Strong autoregulatory mechanisms may provide consistent ocular perfusion in healthy subjects during VM.Keywords
This publication has 27 references indexed in Scilit:
- Comparison of dynamic contour tonometry and noncontact tonometry in ocular hypertension and glaucomaEye, 2008
- The Clinical Utility of Dynamic Contour Tonometry and Ocular Pulse AmplitudeJournal of Glaucoma, 2007
- Corneal structure and biomechanics: impact on the diagnosis and management of glaucomaCurrent Opinion in Ophthalmology, 2006
- Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometerClinical & Experimental Ophthalmology, 2006
- Intraocular Pressure and Ocular Pulse Amplitude Comparisons in Different Types of Glaucoma Using Dynamic Contour TonometryCurrent Eye Research, 2006
- The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometryBritish Journal of Ophthalmology, 2005
- Dynamic Contour TonometryJournal of Glaucoma, 2005
- Comparison of Dynamic Contour Tonometry with Goldmann Applanation TonometryInvestigative Ophthalmology & Visual Science, 2004
- Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertensionBritish Journal of Ophthalmology, 2002
- Intraocular pressure responses to systemic autonomic stimulationEye, 1989