Heart Rate Measurement Using the Built-In Triaxial Accelerometer from a Commercial Digital Writing Device
Open Access
Abstract
Currently, wearable technology is an emerging trend that offers remarkable access to our data through smart devices like smartphones, watches, fitness trackers and textiles. As such, wearable devices can enable health monitoring without disrupting our daily routines. In clinical settings, electrocardiograms (ECGs) and photoplethysmographies (PPGs) are used to monitor heart and respiratory behaviors. In more practical settings, accelerometers can be used to estimate the heart rate when they are attached to the chest. They can also help filter out some noise in ECG signals from movement. In this work, we compare the heart rate data extracted from the built-in accelerometer of a commercial smart pen equipped with sensors (STABILO’s DigiPen) to standard ECG monitor readouts. We demonstrate that it is possible to accurately predict the heart rate from the smart pencil. The data collection is carried out with eight volunteers writing the alphabet continuously for five minutes. The signal is processed with a Butterworth filter to cut off noise. We achieve a mean-squared error (MSE) better than 6.685 × comparing the DigiPen’s computed (time between pulses) with the reference ECG data. The peaks’ timestamps for both signals all maintain a correlation higher than 0.99. All computed heart rates (HR =) from the pen accurately correlate with the reference ECG signals.
Keywords
All Related Versions
Funding Information
- Canada Research Chair
This publication has 50 references indexed in Scilit:
- Characterization and classification of Parkinson’s disease patients based on symbolic dynamics analysis of heart rate variabilityBiomedical Signal Processing and Control, 2022
- COVID‐19, fatigue, and dysautonomiaJournal of Medical Virology, 2020
- Current progress of photoplethysmography and SPO2 for health monitoringBiomedical Engineering Letters, 2019
- Respiratory Rate Estimation by Using ECG, Impedance, and Motion Sensing in Smart ClothingJournal of Medical and Biological Engineering, 2017
- Respiratory rate estimation from the ECG using an instantaneous frequency tracking algorithmBiomedical Signal Processing and Control, 2014
- Capacitive Measurement of ECG for Ubiquitous HealthcareAnnals of Biomedical Engineering, 2014
- Dysautonomia in Parkinson Disease2014
- Smart Vest: Wearable multi-parameter remote physiological monitoring systemMedical Engineering & Physics, 2007
- Heart rate variability: a reviewMedical & Biological Engineering & Computing, 2006
- RR Interval Variation and the Sympathetic Skin Response in the Assessment of Autonomic Function in Peripheral NeuropathyArchives of Neurology, 1990