Shear Wave Velocity Imaging Using Transient Electrode Perturbation: Phantom and ex vivo Validation
- 11 November 2010
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 30 (3) , 666-678
Abstract
This paper presents a new shear wave velocity imaging technique to monitor radio-frequency and microwave ablation procedures, coined electrode vibration elastography. A piezoelectric actuator attached to an ablation needle is transiently vibrated to generate shear waves that are tracked at high frame rates. The time-to-peak algorithm is used to reconstruct the shear wave velocity and thereby the shear modulus variations. The feasibility of electrode vibration elastography is demonstrated using finite element models and ultrasound simulations, tissue-mimicking phantoms simulating fully (phantom 1) and partially ablated (phantom 2) regions, and an ex vivo bovine liver ablation experiment. In phantom experiments, good boundary delineation was observed. Shear wave velocity estimates were within 7% of mechanical measurements in phantom 1 and within 17% in phantom 2. Good boundary delineation was also demonstrated in the ex vivo experiment. The shear wave velocity estimates inside the ablated region were higher than mechanical testing estimates, but estimates in the untreated tissue were within 20% of mechanical measurements. A comparison of electrode vibration elastography and electrode displacement elastography showed the complementary information that they can provide. Electrode vibration elastography shows promise as an imaging modality that provides ablation boundary delineation and quantitative information during ablation procedures.Keywords
This publication has 46 references indexed in Scilit:
- Radiofrequency electrode vibration-induced shear wave imaging for tissue modulus estimation: A simulation studyThe Journal of the Acoustical Society of America, 2010
- In vivo Quantification of Liver Stiffness in a Rat Model of Hepatic Fibrosis with Acoustic Radiation ForceUltrasound in Medicine & Biology, 2009
- Three-Dimensional Electrode Displacement Elastography Using the Siemens C7F2 fourSight Four-Dimensional Ultrasound TransducerUltrasound in Medicine & Biology, 2008
- Quantifying Hepatic Shear Modulus In Vivo Using Acoustic Radiation ForceUltrasound in Medicine & Biology, 2008
- Contrast-transfer improvement for electrode displacement elastographyPhysics in Medicine & Biology, 2006
- Shear wave speed recovery in transient elastography and supersonic imaging using propagating frontsInverse Problems, 2006
- Liver fibrosis: non‐invasive assessment with MR elastographyNMR in Biomedicine, 2006
- Tissue-mimicking agar/gelatin materials for use in heterogeneous elastography phantomsPhysics in Medicine & Biology, 2005
- Necrosis evolution during high-temperature hyperthermia through implanted heat sourcesIEEE Transactions on Biomedical Engineering, 2003
- Vibro-acoustic tissue mammographyIEEE Transactions on Medical Imaging, 2002