Traditional Foley Drainage Systems—Do They Drain the Bladder?
Authors:
- 1 January 2007
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 177 (1) , 203-207
Abstract
Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.Keywords
This publication has 9 references indexed in Scilit:
- Catheter-Related Urinary Tract InfectionDrugs & Aging, 2005
- A chart audit of factors related to urine flow and urinary tract infectionJournal of Advanced Nursing, 2003
- Evaluation of the Antimicrobial Efficacy of Urinary Catheters Impregnated With Antiseptics in an In Vitro Urinary Tract ModelInfection Control & Hospital Epidemiology, 2003
- Epidemiology of urinary tract infectionsInfectious Disease Clinics of North America, 2003
- The migration of Proteus mirabilis and other urinary tract pathogens over Foley cathetersBJU International, 2002
- The characteristics and management of patients with recurrent blockage of long‐term urinary cathetersJournal of Advanced Nursing, 1994
- Nosocomial catheter-associated bacteriuria: a clinical trial comparing two closed urinary drainage systemsJournal of Hospital Infection, 1993
- Surface morphology and friction coefficient of various types of Foley catheterBiomaterials, 1993
- Catheter-Associated Bacteriuria: A Controlled Trial with the BardexRUrinary Drainage SystemActa Obstetricia et Gynecologica Scandinavica, 1986