Common challenges and problems in clinical trials of boron neutron capture therapy of brain tumors
Authors:
- 1 March 2003
- journal article
- review article
- Published by Springer Nature in Journal of Neuro-Oncology
- Vol. 62 (1-2) , 197-210
Abstract
Clinical trials for binary therapies, like boron neutron capture therapy (BNCT), pose a number of unique problems and challenges in design, performance, and interpretation of results. In neutron beam development, different groups use different optimization parameters, resulting in beams being considerably different from each other. The design, development, testing, execution of patient pharmacokinetics and the evaluation of results from these studies differ widely. Finally, the clinical trials involving patient treatments vary in many aspects such as their dose escalation strategies, treatment planning methodologies, and the reporting of data. The implications of these differences in the data accrued from these trials are discussed. The BNCT community needs to standardize each aspect of the design, implementation, and reporting of clinical trials so that the data can be used meaningfully.Keywords
This publication has 46 references indexed in Scilit:
- Modification of the University of Washington Neutron Radiotherapy Facility for optimization of neutron capture enhanced fast‐neutron therapyMedical Physics, 2000
- Boron Neutron-Capture Therapy (BNCT) for Glioblastoma Multiforme (GBM) Using the Epithermal Neutron Beam at the Brookhaven National LaboratoryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1998
- Monte Carlo-based treatment planning for boron neutron capture therapy using custom designed models automatically generated from CT dataInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1996
- Radiation response and survival time in patients with glioblastoma multiformeJournal of Neurosurgery, 1996
- Boron Neutron Capture Therapy of Brain Tumors: Past History, Current Status, and Future PotentialCancer Investigation, 1996
- Performance of sulfhydryl boron hydride in patients with grade III and IV astrocytoma: a basis for boron neutron capture therapyJournal of Neurosurgery, 1995
- Biodistribution of Boron Sulfhydryl for Boron Neutron Capture Therapy in Patients with Intracranial TumorsNeurosurgery, 1995
- Determination of boron in tissues and cells using direct-current plasma atomic emission spectroscopyAnalytical Chemistry, 1991
- Randomized neutron dose searching study for malignant gliomas of the brain: Results of an RTOG studyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1988
- Tumor Extent as A Determining Factor in Radiotherapy of GlioblastomasActa Radiologica: Therapy, Physics, Biology, 1969