DIFFERENT ANALGESIC EFFECTS OF MANUAL AND ELECTRICAL ACUPUNCTURE STIMULATION OF REAL AND SHAM AURICULAR POINTS: A BLIND CONTROLLED STUDY WITH RATS
Authors:
- 1 November 1999
- journal article
- research article
- Published by SAGE Publications in Acupuncture & Electro-Therapeutics Research: International Journal of Integrated Medicine
- Vol. 24 (3-4) , 169-179
Abstract
Stimulation of the auricle is considered to be an effective analgesic technique. The aim of the present study is to establish whether there is a correspondence between somatic inflammation and the appearance of lower resistance points, and moreover, whether the stimulation of such points has an analgesic effect. The study has been conducted on 57 male Sprague-Dawley rats weighing between 120–140 g; 7 of them have been used to determine whether inflammation in the paw leads to the formation of lower resistance points on the auricle. The 50 remaining animals have been divided into 5 groups: Group 1 [12 animals], control were subjected to all manipulations with the exception of the auricle stimulation; Group 2 [12] was stimulated with manual acupuncture in the area corresponding to that observed in the above-mentioned first group of 7 animals; Group 3 [12] was stimulated with 5Hz and 5 mA; electroacupuncture (EAP) Group 4 [8] and group 5 [6] were treated with acupuncture and with EAP respectively on points believed to be inactive in areas diametrically opposite to the ones observed in the first group. After acupuncture, 100 μg capsaicin in 50μL of physiological solution were injected subcutis in the dorsal surface of the paw. Edema response was monitored for two hours, with measurement taken every 5 minutes. The results show a reduction in the edema response, only in the group treated with EAP on the appropriate points compared to the control group; no variation was observed in the sham groups. To conclude, the hypothesis of a somatotopic division would seem to be probable, and it would seem that the stimulation of the appropriate areas and the use of an appropriate intensity constitute the two main variables influencing the result.Keywords
This publication has 16 references indexed in Scilit:
- Parametric Studies on Electroacupuncture-Like Stimulation in a Rat Model: Effects of Intensity, Frequency, and Duration of Stimulation on Evoked AntinociceptionBrain Research Bulletin, 1997
- The distribution of brain-stem and spinal cord nuclei associated with different frequencies of electroacupuncture analgesiaPain, 1993
- Modulation of neurogenic inflammation: novel approaches to inflammatory diseaseTrends in Pharmacological Sciences, 1990
- The rat paw formalin test: comparison of noxious agentsPain, 1990
- Effects of opioids on the heat stimulus-evoked substance P release and thermal edema in the rat hind pawEuropean Journal of Pharmacology, 1988
- Effects of Unilateral and Bilateral Auricular Transcutaneous Electrical Nerve Stimulation on Cutaneous Pain ThresholdPhysical Therapy, 1987
- Effects of Auricular Transcutaneous Electrical Nerve Stimulation on Experimental Pain ThresholdPhysical Therapy, 1986
- Auriculotherapy Fails to Relieve Chronic PainJAMA, 1984
- Inhibition of neurogenic vasodilatation and plasma extravasation by substance P antagonists, somatostatin and [D-Met2, Pro5]enkephalinamideEuropean Journal of Pharmacology, 1982
- Opiate agonists inhibit neurogenic plasma extravasation in the ratEuropean Journal of Pharmacology, 1981