Measurement of plasma cardiac troponin I concentration by use of a point-of-care analyzer in clinically normal horses and horses with experimentally induced cardiac disease
Authors:
- Marc S. KrausMKMarc S. Kraus
- Sophy A. JestySJSophy A. Jesty
- Anna R. GelzerAGAnna R. Gelzer
- Norm G. DucharmeNDNorm G. Ducharme
- Hussni O. MohammedHMHussni O. Mohammed
- Lisa M. MitchellLMLisa M. Mitchell
- Leo V. SoderholmLSLeo V. Soderholm
- Thomas J. DiversTDThomas J. Divers
- 1 January 2010
- journal article
- research article
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 71 (1) , 55-59
Abstract
Objective—To compare cardiac troponin I (cTnI) concentrations determined by use of a point-of-care analyzer with values determined by use of a bench-top immunoassay in plasma samples obtained from clinically normal horses with and without experimentally induced cardiac disease, and to establish a reference range for plasma equine cTnI concentration determined by use of the point-of-care analyzer. Animals—83 clinically normal horses, 6 of which were administered monensin to induce cardiac disease. Procedures—A blood sample was collected from each of the 83 clinically normal horses to provide plasma for analysis by use of the point-of-care analyzer; some of the same samples were also analyzed by use of the immunoassay. All 83 samples were used to establish an analyzer-specific reference range for plasma cTnI concentration in clinically normal horses. In 6 horses, blood samples were also collected at various time points after administration of a single dose of monensin (1.0 to 1.5 mg/kg) via nasogastric intubation; plasma cTnI concentration in those samples was assessed by use of both methods. Results—The analyzer-specific reference range for plasma cTnI concentration in clinically normal horses was 0.0 to 0.06 ng/mL. Following monensin treatment in 5 horses, increases in plasma cTnI concentration determined by use of the 2 methods were highly correlated (Pearson correlation, 0.83). Peak analyzer-determined plasma cTnI concentrations in monensin-treated horses ranged from 0.08 to 3.68 ng/mL. Conclusions and Clinical Relevance—In horses with and without experimentally induced cardiac disease, the point-of-care analyzer and bench-top immunoassay provided similar values of plasma cTnI concentration.Keywords
This publication has 29 references indexed in Scilit:
- Cardiac troponinsJournal of Veterinary Emergency and Critical Care, 2008
- Transvenous Electrical Cardioversion of Equine Atrial Fibrillation: Patient Factors and Clinical Results in 72 Treatment EpisodesJournal of Veterinary Internal Medicine, 2008
- Evaluation of serum cardiac troponin I concentration in Boxers with arrhythmogenic right ventricular cardiomyopathyAmerican Journal of Veterinary Research, 2007
- Cardiovascular Effects of Acute Pulmonary Obstruction in Horses with Recurrent Airway ObstructionJournal of Veterinary Internal Medicine, 2007
- Serum and plasma cardiac troponin I concentrations in clinically normal Thoroughbreds in training in AustraliaAustralian Veterinary Journal, 2006
- Cardiac troponin I in canine patients with lymphoma and osteosarcoma receiving doxorubicin: comparison with clinical heart disease in a retrospective analysisVeterinary and Comparative Oncology, 2004
- Cardiac Troponin I in Pastured and Race-Training Thoroughbred HorsesJournal of Veterinary Internal Medicine, 2003
- High Cardiac Troponin I Serum Concentration in a Horse with Multiform Ventricular Tachycardia and Myocardial NecrosisJournal of Veterinary Internal Medicine, 2003
- Concentration of cardiac troponin I in a horse with a ruptured aortic regurgitation jet lesion and ventricular tachycardiaJournal of the American Veterinary Medical Association, 2000
- Cantharidin Toxicosis in HorsesJournal of Veterinary Internal Medicine, 1989