Recurrent atrial arrhythmia in a randomised controlled trial comparing contact force–guided and contact force–blinded ablation for typical atrial flutter
- 13 January 2022
- journal article
- research article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 63 (3) , 699-707
Abstract
Background Contact force (CF)–guided catheter ablation (CA) is a novel technology developed to improve efficacy and reduce complications. In a randomised controlled trial (RCT), we previously documented that after 3 months, rate of persistent conduction block was similar with and without using CF while performing CA for typical atrial flutter (AFL). Clinical effect of CF on recurrent arrhythmia is unknown. Our objective is to study recurrent atrial arrhythmia during 12-month follow-up in a RCT investigating whether CF-guided CA for typical AFL is superior to CF-blinded CA. Methods Patients were randomised 1:1 to CA guided by CF (intervention group) or blinded to CF (control group). After 12 months, patients attended clinical check-up preceded by a 5-day ambulatory Holter monitor recording. Primary outcome was any recurrent atrial arrhythmia ≥ 30 s within 12 months and documented in 12-lead ECG or Holter monitor recording. Results We included 156 patients, four patients withdrew consent and two died during follow-up. Thus, 150 patients were included in final analysis. Recurrent arrhythmia was detected in 36 of 77 (47%) patients in the intervention group, and 32 of 73 patients (44%) in the control group (p = 0.51). Atrial fibrillation was detected in 23 (30%) and 29 (40%) patients in the intervention and control groups respectively. AFL was detected in 11 (14%) and 5 (7%) patients in the intervention and control groups respectively. Conclusions Contact force–guided ablation for typical atrial flutter does not reduce recurrent atrial arrhythmia after 12-month follow-up as compared with ablation blinded for contact force. Graphical abstractKeywords
All Related Versions
Funding Information
- Abbot
This publication has 26 references indexed in Scilit:
- Incidence of new-onset atrial fibrillation after cavotricuspid isthmus ablation for atrial flutterEP Europace, 2017
- Incidence of Atrial Fibrillation After Atrial Flutter AblationJACC: Clinical Electrophysiology, 2016
- Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force–Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial FibrillationCirculation, 2015
- HATCH score in the prediction of new-onset atrial fibrillation after catheter ablation of typical atrial flutterHeart Rhythm, 2015
- High Incidence of Low Catheter‐Tissue Contact Force at the Cavotricuspid Isthmus During Catheter Ablation of Atrial Flutter: Implications for Achieving Isthmus BlockJournal of Cardiovascular Electrophysiology, 2015
- EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillationEP Europace, 2015
- Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial TreatmentCirculation: Arrhythmia and Electrophysiology, 2013
- The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA studyHeart Rhythm, 2012
- Catheter ablation of atrial arrhythmias: state of the artThe Lancet, 2012
- Inter-Relationships of Atrial Fibrillation and Atrial FlutterJACC, 2008