Abstract
The AMoRE collaboration searches for neutrinoless double beta decay of $$^{100}$$ 100 Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $$^{100}$$ 100 Mo isotope, is under construction. This paper discusses the baseline design and characterization of the lithium molybdate cryogenic calorimeters to be used in the AMoRE-II detector modules. The results from prototype setups that incorporate new housing structures and two different crystal masses (316 g and 517–521 g), operated at 10 mK temperature, show energy resolutions (FWHM) of 7.55–8.82 keV at the 2.615 MeV $$^{208}$$ 208 Tl $$\gamma $$ γ line and effective light detection of 0.79–0.96 keV/MeV. The simultaneous heat and light detection enables clear separation of alpha particles with a discrimination power of 12.37–19.50 at the energy region around $$^{6}$$ 6 Li $$(n,\alpha )^3$$ ( n , α ) 3 H with Q-value = 4.785 MeV. Promising detector performances were demonstrated at temperatures as high as 30 mK, which relaxes the temperature constraints for operating the large AMoRE-II array.
Funding Information
  • National Research Foundation of Ukraine (2023.03/0213)
  • Deutsche Forschungsgemeinschaft (GA 2219/4-1)
  • Institute for Basic Science (IBS-R016-A2, IBS-R016-D1)
  • Ministry of Science and Higher Education of the Russian Federation (N121031700314-5)
  • National Research Foundation (2021R1A2C1013761, 2023K2A9A2A22091340, NRF-2021R1I1A3041453)
  • NFEC (No. 2019R1A6C1010027)

This publication has 37 references indexed in Scilit: