3D diffusion tensor MRI with isotropic resolution using a steady‐state radial acquisition
Open Access
- 22 April 2009
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 29 (5) , 1175-1184
Abstract
Purpose: To obtain diffusion tensor images (DTI) over a large image volume rapidly with 3D isotropic spatial resolution, minimal spatial distortions, and reduced motion artifacts, a diffusion‐weighted steady‐state 3D projection (SS 3DPR) pulse sequence was developed.Materials and Methods: A diffusion gradient was inserted in a SS 3DPR pulse sequence. The acquisition was synchronized to the cardiac cycle, linear phase errors were corrected along the readout direction, and each projection was weighted by measures of consistency with other data. A new iterative parallel imaging reconstruction method was also implemented for removing off‐resonance and undersampling artifacts simultaneously.Results: The contrast and appearance of both the fractional anisotropy and eigenvector color maps were substantially improved after all correction techniques were applied. True 3D DTI datasets were obtained in vivo over the whole brain (240 mm field of view in all directions) with 1.87 mm isotropic spatial resolution, six diffusion encoding directions in under 19 minutes.Conclusion: A true 3D DTI pulse sequence with high isotropic spatial resolution was developed for whole brain imaging in under 20 minutes. To minimize the effects of brain motion, a cardiac synchronized, multiecho, DW‐SSFP pulse sequence was implemented. Motion artifacts were further reduced by a combination of linear phase correction, corrupt projection detection and rejection, sampling density reweighting, and parallel imaging reconstruction. The combination of these methods greatly improved the quality of 3D DTI in the brain. J. Magn. Reson. Imaging 2009;29:1175–1184.Keywords
This publication has 29 references indexed in Scilit:
- Consistent non‐cartesian off‐axis MRI quality: Calibrating and removing multiple sources of demodulation phase errorsMagnetic Resonance in Medicine, 2006
- Isotropic diffusion weighting in radial fast spin‐echo magnetic resonance imagingMagnetic Resonance in Medicine, 2005
- 3D DT‐MRI using a reduced‐FOV approach and saturation pulsesMagnetic Resonance in Medicine, 2004
- High‐resolution diffusion‐weighted 3D MRI, using diffusion‐weighted driven‐equilibrium (DW‐DE) and multishot segmented 3D‐SSFP without navigator echoesMagnetic Resonance in Medicine, 2003
- Nonlinear phase correction for navigated diffusion imagingMagnetic Resonance in Medicine, 2003
- High‐resolution isotropic 3D diffusion tensor imaging of the human brainMagnetic Resonance in Medicine, 2002
- Diffusion-weighted imaging of the spine using radial k-space trajectoriesMagnetic Resonance Materials in Physics, Biology and Medicine, 2001
- Analysis and comparison of motion‐correction techniques in diffusion‐weighted imagingJournal of Magnetic Resonance Imaging, 1996
- Use of a projection reconstruction method to decrease motion sensitivity in diffusion-weighted MRIMagnetic Resonance in Medicine, 1993
- Reduction of flow artifacts in NMR diffusion imaging using view‐angle tilted line‐integral projection reconstructionMagnetic Resonance in Medicine, 1991