Influence of multiple clinical use on fatigue resistance of ProTaper rotary nickel‐titanium instruments
- 14 November 2007
- journal article
- Published by Wiley in International Endodontic Journal
- Vol. 41 (2) , 163-172
Abstract
Aim To examine the influence of clinical use on the occurrence of deformation and fracture and on the fatigue resistance of ProTaper rotary instruments. Methodology Root canal treatments were performed on patients using the ProTaper rotary system. Ten sets of instruments were used by an experienced endodontist, each set in five molars. Another 10 sets of instruments were used by the same operator, each set in eight molars. In addition, 10 sets of instruments were used, each set in five molars, by undergraduate students with no clinical experience with the system. After clinical use, S1, S2, F1 and F2 instruments were analysed for damage by optical and scanning electron microscopy. The used sets, along with a control group of 12 sets of new instruments, were then tested in a bench device for fatigue resistance. Results The use of the ProTaper rotary instruments by an experienced endodontist allowed for the cleaning and shaping of the root canal system of up to eight molars without fracture. During the students work, six instruments fractured. Fatigue resistance decreased upon clinical use for all instruments analysed. Conclusions Fatigue resistance of used instruments was reduced, but no significant change was observed amongst the instruments used for shaping the canals of five and eight molars. Operator experience affected the occurrence of fracture and plastic deformation during shaping.Keywords
This publication has 33 references indexed in Scilit:
- Physical and mechanical characterization and the influence of cyclic loading on the behaviour of nickel‐titanium wires employed in the manufacture of rotary endodontic instrumentsInternational Endodontic Journal, 2005
- Defects in ProTaper S1 instruments after clinical use: fractographic examinationInternational Endodontic Journal, 2005
- Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canalsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2005
- SEM evaluation of canal wall dentine following use of Mtwo and ProTaper NiTi rotary instrumentsInternational Endodontic Journal, 2004
- Structural and functional fatigue of NiTi shape memory alloysMaterials Science and Engineering: A, 2004
- Influence of Manual Preflaring and Torque on the Failure Rate of ProTaper Rotary InstrumentsJournal of Endodontics, 2004
- Cyclic fatigue testing of ProTaper NiTi rotary instruments after clinical useOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2004
- Evaluation of Single-use Rotary Nickel-titanium InstrumentsJournal of Endodontics, 2003
- Scanning Electron Microscope Observations of New and Used Nickel-Titanium Rotary FilesJournal of Endodontics, 2003
- Wear of nickel-titanium lightspeed instruments evaluated by scanning electron microscopyJournal of Endodontics, 1999