Limitations of methods for measuring the concentration of human genomic DNA and oligonucleotide samples
Open Access
- 1 February 2018
- journal article
- research article
- Published by Taylor & Francis in BioTechniques
- Vol. 64 (2) , 59-68
Abstract
We compared different methods (absorbance, fluorescent dye-binding, and digital PCR) for measuring the concentrations of human genomic DNA from cultured cells and absorbance measurements of a synthetic DNA oligonucleotide. NIST Standard Reference Material (SRM) 2082, a pathlength absorbance standard, was used to benchmark the absorbance measurements done with microvolume spectrophotometers and a microvolume plate reader. Control absorbance values were measured on a high accuracy spectrophotometer and a NIST calibrated pathlength cuvette. Measurements of the human genomic DNA sample were done with several types of fluorescent dye binding assays using different DNA calibrators. The fluorescent dye binding methods gave different results for genomic DNA depending upon the type of DNA calibrator and the fluorescent dye that was used. The human genomic DNA sample was also characterized by using six different droplet digital PCR assays (amplicons located on different chromosomes) to measure the average copy number. Conversion of the digital PCR data to copy numbers was sensitive to the droplet size used for calculations and conversion to mass concentration was dependent upon the molecular weight of the human genome used for the calculations. The results from the different methods were compared and the caveats for each measurement method were discussed.Keywords
This publication has 26 references indexed in Scilit:
- The Digital MIQE Guidelines: Minimum Information for Publication of Quantitative Digital PCR ExperimentsClinical Chemistry, 2013
- High-Throughput Droplet Digital PCR System for Absolute Quantitation of DNA Copy NumberAnalytical Chemistry, 2011
- Characterization of PicoGreen Interaction with dsDNA and the Origin of Its Fluorescence Enhancement upon BindingBiophysical Journal, 2010
- Comparison of Methods for Accurate Quantification of DNA Mass Concentration with Traceability to the International System of UnitsAnalytical Chemistry, 2010
- Contrasting GC-content dynamics across 33 mammalian genomes: Relationship with life-history traits and chromosome sizesGenome Research, 2010
- Assay for the quantification of intact/fragmented genomic DNAAnalytical Biochemistry, 2006
- Letter to the editorCytometry Part A, 2003
- Characterization of PicoGreen Reagent and Development of a Fluorescence-Based Solution Assay for Double-Stranded DNA QuantitationAnalytical Biochemistry, 1997
- An approach to high-throughput genotyping.Genome Research, 1996
- Sequence and organization of the human mitochondrial genomeNature, 1981