Assessment of value of calibrated lyophilised plasmas to determine International Sensitivity Index for coagulometers.
Authors:
- D A TabernerDTD A Taberner
- J M ThomsonJTJ M Thomson
- J A MorrisJMJ A Morris
- L PollerLPL Poller
Open Access
- 1 January 1992
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 45 (1) , 58-60
Abstract
An attempt was made to correct for the effects of coagulometers on the International Sensitivity Index (ISI) in a series of collaborative studies. Modified ISI were derived from the prothrombin time results with coagulometer systems using a range of calibrated plasmas. Two alternative approaches to correction of the ISI were evaluated. The first relied on the consensus orthogonal regression slopes of the prothrombin times for each coagulometer system plotted against the consensus manual results; the second depended on the local individual slope of the prothrombin times for each instrument. The two procedures were compared with the currently recommended method where International Normalised Ratios (INR) are derived from the manual ISI of the thromboplastin. The recommended method gave a significant bias from the manual results with most coagulometers. In contrast, the local correction procedure gave no significant biases, whereas the consensus method did so in a few instances. Both these correction procedures seem more reliable than the recommended method of INR derivation, but the local correction is more accurate and offers a more practical solution by allowing laboratories to determine their own corrected ISI on a range of calibrated plasmas.Keywords
This publication has 8 references indexed in Scilit:
- Statistical Modelling in GLIMTechnometrics, 1991
- Automation and prothrombin time: a United Kingdom field study of two widely used coagulometers.Journal of Clinical Pathology, 1990
- The Dependence of the International Sensitivity Index on the Coagulometer Used to Perform the Prothrombin TimeThrombosis and Haemostasis, 1990
- The Effect of Some Instruments for Prothrombin Time Testing on the International Sensitivity Index (ISI) of Two Rabbit Tissue Thromboplastin ReagentsThrombosis and Haemostasis, 1989
- Effect of automation on prothrombin time test in NEQAS surveys.Journal of Clinical Pathology, 1989
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Effect of thromboplastin and instrumentation on the prothrombin time test.1981
- Automated versus Manual Techniques for the Prothrombin Time Test: Results of Proficiency Assessment StudiesBritish Journal of Haematology, 1978