Abstract
Compartment effects in hemodialysis are important because they reduce the efficiency of removal of the compartmentalized solute during dialysis. The dialyzer can only remove those waste products that are presented to it, and then only in proportion to the concentration of the solute in the blood. Classically a two‐compartment system has been modeled, with the compartments arranged in series. Because modeling suggests that the sequestered compartment is larger than the accessible compartment, an assumption has been made that the sequestered compartment is the intracellular space. For urea and other solutes that move easily across many cell membranes, compartmentalization may be flow related, that is, related to sequestration in organs (muscle, skin, bone). Although mathematically urea rebound and mass balance can be described with either model, the flow‐related model best explains data showing that urea rebound after dialysis is increased during ultrafiltration, diminished during high cardiac output states, and also reduced during exercise. Whether compartmentalization is increased in vasoconstricted intensive care unit patients receiving acute dialysis remains an open question.Keywords
This publication has 30 references indexed in Scilit:
- Multicompartment urea kinetics in well-dialyzed childrenKidney International, 2000
- Solute Clearance and Tissue Clearance TimesSeminars in Dialysis, 1998
- Cardiac output and urea kinetics in dialysis patients: Evidence supporting the regional blood flow modelKidney International, 1996
- Recirculation and the post-dialysis reboundNephrology Dialysis Transplantation, 1996
- Overestimation of Hemodialysis Dose Depends on Dialysis Efficiency by Regional Blood Flow but not by Conventional Two Pool Urea Kinetic AnalysisASAIO Journal, 1995
- Hemodialysis urea rebound: The effect of increasing dialysis efficiencyAmerican Journal of Kidney Diseases, 1995
- Formal Analytical Solution to a Regional Blood Flow and Diffusion Based Urea Kinetic ModelASAIO Journal, 1994
- Patient Related Factors Leading to Slow Urea Transfer in the Body During DialysisASAIO Journal, 1994
- Urea kinetics during hemodialysis measured by microdialysis—A novel techniqueKidney International, 1993
- A Regional Blood Circulation Alternative to In-series Two Compartment Urea Kinetic ModelingASAIO Journal, 1993