Reading performance and patient satisfaction after corneal inlay implantation for presbyopia correction: Two-year follow-up
Authors:
- Alois K. DexlADAlois K. Dexl
- Orang SeyeddainOSOrang Seyeddain
- Wolfgang RihaWRWolfgang Riha
- Theresa RücklTRTheresa Rückl
- Alexander BacherneggABAlexander Bachernegg
- Martin EmeszMEMartin Emesz
- Josef RuckhoferJRJosef Ruckhofer
- Günther GrabnerGGGünther Grabner
- 1 October 2012
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (10) , 1808-1816
Abstract
To evaluate change in reading performance parameters after monocular Kamra corneal inlay implantation for the surgical correction of presbyopia. University surgical outpatient center. Prospective interventional case series. A corneal inlay was implanted in the nondominant eye. Naturally emmetropic and presbyopic patients between 45 years and 60 years old with an uncorrected distance visual acuity of at least 20/20 in both eyes without additional ocular pathology were eligible for inclusion. Bilateral uncorrected reading acuity, reading distance, mean and maximum reading speed, and the smallest log-scaled print size (lower case letter of a Radner reading chart) were evaluated using the Salzburg Reading Desk. The minimum postoperative follow-up was 24 months. Twenty-four patients were enrolled. The mean reading distance was 46.7 cm ± 6.3 (SD) preoperatively and 39.5 ± 6.4 cm 24 months postoperatively (P<.001). The mean reading acuity at best distance improved (0.33 ± 0.13 logRAD versus 0.23 ± 0.11 logRAD) (P=.004). The mean reading speed increased from 141 ± 20 words per minute (wpm) to 146 ± 20 wpm, respectively (P=.261), and the mean maximum reading speed from 171 ± 28 wpm to 180 ± 22 wpm, respectively (P=.110). The smallest print size improved from 1.50 ± 0.42 mm to 1.01 ± 0.22 mm, respectively (P<.001). Improving the depth of focus by monocular implantation of a small-aperture optic caused statistically significant changes in all tested reading performance parameters except reading speed metrics in emmetropic presbyopic patients.Keywords
This publication has 17 references indexed in Scilit:
- Reading Performance After Implantation of a Modified Corneal Inlay Design for the Surgical Correction of Presbyopia: 1-Year Follow-upAmerican Journal of Ophthalmology, 2012
- One-year visual outcomes and patient satisfaction after surgical correction of presbyopia with an intracorneal inlay of a new designJournal of Cataract & Refractive Surgery, 2012
- Intracorneal inlay to correct presbyopia: Long-term resultsJournal of Cataract & Refractive Surgery, 2011
- Reading performance after implantation of a small-aperture corneal inlay for the surgical correction of presbyopia: Two-year follow-upJournal of Cataract & Refractive Surgery, 2011
- Corneal Inlays for the Treatment of PresbyopiaInternational Ophthalmology Clinics, 2011
- Hydrogel Intracorneal Inlays for the Correction of HyperopiaOphthalmology, 2009
- Intracorneal inlay for the surgical correction of presbyopiaJournal of Cataract & Refractive Surgery, 2008
- Polyvinylidene fluoride (PVDF) as a biomaterial: From polymeric raw material to monofilament vascular sutureJournal of Biomedical Materials Research, 1995
- Histopathology and Clinical Behavior of Polysulfone Intracorneal Implants in the Baboon ModelOphthalmology, 1988
- Polysulfone corneal lensesJournal of Cataract & Refractive Surgery, 1986