Percutaneous therapies for congenital heart disease have been evolving rapidly despite limited investment from industry. The Melody transcatheter pulmonary valve (Medtronic, Inc, Minneapolis, MN USA) replacement therapy represents an important advancement in this arena. It has been approved in the United States for use in the pulmonary position, on a Humanitarian Device Exemption status. Off-label use of the Melody transcatheter pulmonary valve has extended to the mitral, pulmonary, and aortic valves, especially in previously implanted valves with prosthetic valve degeneration. The single-ventricle patient poses additional challenges. However, there exists one report in the English literature of a patient undergoing Melody transcatheter neoaortic valve replacement after the patient developed severe neoaortic regurgitation after Fontan palliation. Here, we describe a patient with hypoplastic left heart syndrome, palliated with a Norwood modified Blalock-Taussig shunt, with a progressively regurgitant quadricusp neoaortic valve who underwent bioprosthetic valve replacement. There was early prosthetic valve degeneration after a year of bioprosthesis implantation. As he was declined for transplantation, he underwent successful perventricular Melody valve-in-valve replacement.Keywords
This publication has 8 references indexed in Scilit:
- Concept of an expandable cardiac valve for surgical implantation in infants and childrenThe Journal of Thoracic and Cardiovascular Surgery, 2016
- First successful trans-catheter aortic-valve replacement for native aortic stenosis in atrio-pulmonary FontanInternational Journal of Cardiology, 2016
- Transapical valve-in-valve implantation to treat a regurgitant mitral bioprothesis in a child with failing Fontan circulationThe Journal of Thoracic and Cardiovascular Surgery, 2015
- Transcatheter neoaortic valve replacement utilizing the melody valve in hypoplastic left heart syndromeCatheterization and Cardiovascular Interventions, 2014
- Regional left ventricular function after transapical vs. transfemoral transcatheter aortic valve implantation analysed by cardiac magnetic resonance feature trackingEuropean Heart Journal - Cardiovascular Imaging, 2014
- Transcatheter pulmonary valve insertion, expanded use (beyond large conduits from the right ventricle to pulmonary artery), and future directionsCardiology in the Young, 2014
- Short-Term Performance of the Transcatheter Melody Valve in High-Pressure Hemodynamic Environments in the Pulmonary and Systemic CirculationsCirculation: Cardiovascular Interventions, 2011
- Immunology and failure of valved allografts in childrenThe Annals of Thoracic Surgery, 2002