Solid-phase micro extraction (SPME) and headspace derivatization of clenbuterol followed by GC–FID and GC–SIMMS quantification
Authors:
- D. HinzDHD. Hinz
- B. W. WenclawiakBWB. W. Wenclawiak
- 4 January 2003
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 375 (3) , 460-464
Abstract
Solid-phase micro extraction (SPME) and on-fiber derivatization followed by Gas Chromatography coupled with Flame Ionization Detection (GC–FID) or Selected Ion Monitoring Mass Spectrometry (GC–SIMMS) allows for simple yet sensitive quantification for the hexamethyldisilazane derivative of the β-agonist clenbuterol. Using an 85-µm polyacrylate fiber, the analysis method is optimized with respect to extraction time, derivatization time and temperature, and solution pH. In addition, the use of a rapid temperature ramping injection port allows for optimization of fiber desorption conditions. Under optimal conditions, the limits of detection for the hexamethyldisilazane derivative of clenbuterol are 1.1 ppb by FID and 0.20 ppb by SIMMS.Keywords
This publication has 17 references indexed in Scilit:
- Fully Automated Determination of Amphetamines and Synthetic Designer Drugs in Hair Samples Using Headspace Solid-Phase Microextraction and Gas Chromatography--Mass SpectrometryJournal of Chromatographic Science, 2002
- Determination of clenbuterol in human urine by GC–MS–MS–MS: confirmation analysis in antidoping controlJournal of Chromatography B, 2002
- Automated sample preparation using in-tube solid-phase microextraction and its application – a reviewAnalytical and Bioanalytical Chemistry, 2002
- Hair Analysis of Seven Bodybuilders for Anabolic Steroids, Ephedrine, and ClenbuterolJournal of Forensic Sciences, 2002
- Development of clenbuterol reference materials: lyophilized bovine eye samples free of clenbuterol (CRM 673) and containing clenbuterol (CRM 674)Analytical and Bioanalytical Chemistry, 2001
- Clinical and pharmacological profile in a clenbuterol epidemic poisoning of contaminated beef meat in ItalyToxicology Letters, 2000
- Determination of 2-Agonists in Bovine Urine: Comparison of Two Extraction/Clean-Up Procedures for High-Resolution Gas Chromatography-Mass Spectrometry AnalysisJournal of Analytical Toxicology, 2000
- Polyamine-mediated Heart Hypertrophy Induced by Clenbuterol in the MouseJournal of Pharmacy and Pharmacology, 1998
- Drugs and SportSports Medicine, 1997
- Detection and Confirmation of β-Agonists in Bovine Retina Using LC/APCI-MSAnalytical Chemistry, 1996