Feasibility and clinical utility of handheld fundus cameras for retinal imaging
Open Access
- 12 January 2022
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 37 (2) , 274-279
Abstract
Background/objectives: Handheld fundus cameras are portable and cheaper alternatives to table-top counterparts. To date there have been no studies comparing feasibility and clinical utility of handheld fundus cameras to table-top devices. We compare the feasibility and clinical utility of four handheld fundus cameras/retinal imaging devices (Remidio NMFOP, Volk Pictor Plus, Volk iNview, oDocs visoScope) to a table-top camera (Zeiss VisucamNM/FA). Subjects/methods: Healthy participants (n = 10, mean age ± SD = 21.0 ± 0.9 years) underwent fundus photography with five devices to assess success/failure rates of image acquisition. Participants with optic disc abnormalities (n = 8, mean age ± SD = 26.8 ± 15.9) and macular abnormalities (n = 10, mean age ± SD = 71.6 ± 15.4) underwent imaging with the top three scoring fundus cameras. Images were randomised and subsequently validated by ophthalmologists masked to the diagnoses and devices used. Results: Image acquisition success rates (100%) were achieved in non-mydriatic and mydriatic settings for Zeiss, Remidio and Pictor, compared with lower success rates for iNview and oDocs. Image quality and gradeability were significantly higher for Zeiss, Remidio and Pictor (p < 0.0001) compared to iNview and oDocs. For cup:disc ratio estimates, similar levels of bias were seen for Zeiss (−0.09 ± SD:0.15), Remidio (−0.07 ± SD:0.14) and Pictor (−0.05 ± SD:0.16). Diagnostic sensitivities were highest for Zeiss (84.9%; 95% CI, 78.2–91.5%) followed by Pictor (78.1%; 95% CI, 66.6–89.5%) and Remidio (77.5%; 95% CI, 65.9–89.0%). Conclusions: Remidio and Pictor achieve comparable results to the Zeiss table-top camera. Both devices achieved similar scores in feasibility, image quality, image gradeability and diagnostic sensitivity. This suggests that these devices potentially offer a more cost-effective alternative in certain clinical scenarios.Keywords
Funding Information
- DH | National Institute for Health Research (CL-2017-11-003)
This publication has 12 references indexed in Scilit:
- MII RetCam assisted smartphone-based fundus imaging (MSFI)—A boon for paediatric retinal imagingEye, 2020
- Sensitivity and Specificity of Smartphone-Based Retinal Imaging for Diabetic RetinopathyOphthalmology Retina, 2019
- Opinion and Special Articles: Amateur fundus photography with various new devices Our experience as neurology residentsNeurology, 2018
- Automated diabetic retinopathy detection in smartphone-based fundus photography using artificial intelligenceEye, 2018
- Optic nerve head edema among patients presenting to the emergency departmentNeurology, 2018
- Smartphone Assisted Fundus Fundoscopy/PhotographyCurrent Ophthalmology Reports, 2018
- Development and Validation of a Deep Learning Algorithm for Detection of Diabetic Retinopathy in Retinal Fundus PhotographsJAMA, 2016
- Evaluation of Nonmydriatic Hand-held Optic Disc Photography Grading in the Philadelphia Glaucoma Detection and Treatment ProjectJournal of Glaucoma, 2016
- Fundus Photography in the 21st Century—A Review of Recent Technological Advances and Their Implications for Worldwide HealthcareTelemedicine and e-Health, 2016
- Retinal Imaging and Image AnalysisIEEE Reviews in Biomedical Engineering, 2010